36
Horizontal
Measure using 9-12-3
Preparations
Follow the preparations as described in the previous pages.
1. Mount the measuring units.
2.
Enter distances, confirm each distance with
OK
.
3. If needed, perform a rough alignment.
4. If needed, perform a Softfoot check.
Measure
1. Select
and
to switch to 9-12-3.
2. Adjust laser to the centre of the targets. If needed, adjust the units on the rods, then use
laser adjustments knobs.
3. Turn shafts to 9 o’clock.
4. Press
to register first position. The first position is automatically set to zero.
5. Turn shafts to 12 o’clock.
6. Press to register second position.
7. Turn shafts to 3 o’clock.
8. Press to register third position. The Result and adjust view is displayed. See
Function buttons
Back
. Measure previous position or back to Distance view.
See
Switch to the EasyTurn™ method.
Switch to the 9-12-3 method.
Switch to the Horizontal Multipoint method.
See
Edge warning
When the laser beam is
close to the edge, the edge
is “lit up” as a warning. It
is not possible to register
values when you see the
edge warning.
Edge warning
First position is auto-
matically set to zero
www.
GlobalTestSupply
.com
Find Quality Products Online at:
Содержание Easy-Laser E420
Страница 2: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Страница 26: ...22 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Страница 28: ...24 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Страница 34: ...30 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Страница 56: ...52 Technical Data www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Страница 58: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...