33
Horizontal
Adjust measuring units
Place the Measuring units on the rods, make sure they are at the approximately same
rotational angle. You need to place the measuring units with an offset, see image. Also
make sure that the adjustment knob is adjustable in both directions.
Image showing measuring units for E530 system.
1. Place the Measuring units at 9
o’clock. Adjust the laser line to
the centre of both targets. Use
the adjustment knob and/or
move the detectors on the rods.
2. Turn the shafts 180º. Make a
mark on the rods or machine
halfway between the laser line
and centre of both targets.
3. Adjust the laser beams half way
to the centre of targets. Use the
adjustment knobs and/or move
the detectors on the rods.
4. Adjust the movable machine un-
til the laser beam hits the centre
of both targets.
5. Turn the shafts 180º. Check if
both laser lines hit the targets. If
not, repeat step 3–5.
Turn shafts to 12 o’clock. Repeat all
steps for vertical adjustment.
12
6
3
9
12
6
3
9
12
6
3
9
12
6
3
9
12
6
3
9
www.
GlobalTestSupply
.com
Find Quality Products Online at:
Содержание Easy-Laser E420
Страница 2: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Страница 26: ...22 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Страница 28: ...24 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Страница 34: ...30 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Страница 56: ...52 Technical Data www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Страница 58: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...