8
Spyder2 User’s Manual
03-32-10091-04
DALSA
Camera
Performance
Units
Min.
Nom.
Max.
Notes
Random Noise
DN rms
0.5
0.75
2.2
1.2
4
@-10dB gain
@0dB gain
@+10dB gain
Calibrated DC Offset
DN
3
5
17
@-10dB gain
@0dB gain
@+10dB gain
Antiblooming
100x
Responsivity DN/(nJ/
cm
2
)
13.6±2
42.8±5
136.0±16
@-10dB gain
@0dB gain
@+10dB gain
Power Up Duration
sec
15
SEE nJ/cm
2
5.79
@530nm, 0dB
NEE
pJ/cm
2
37.3
@530nm, 0dB
Regulatory
Regulatory Compliance
CE
Shock and Vibration
MIL-STD-810E
DN = Digital Numbers (0-255); also known as gray levels.
1. ECD= Exposure control disabled. When operating the camera in exposure mode 2
(see section 3.9 Setting Line Rate and Exposure Mode for details), exposure control is
disabled until the
set
command is sent. All other exposure modes operate with ECE
or exposure control enabled.
Test conditions unless otherwise noted:
• All measurements taken in 8 bit mode
• Data Rate: 40 MHz
• Line Rate: maximum (FPN and PRNU measured at minimum line rate), DC-Offset to
be characterized over different line rates
• Nominal Gain setting, unless specified
• Light Source: Broadband Quartz Halogen, 3250K, with 750nm cutoff filter installed
• Ambient test temperature: 25
°
C.
• De-rating specifications for temperature range from 0
°
C to 50
°
C.
Содержание Spyder2 S2-1-40 Series
Страница 1: ...Spyder2 Camera User s Manual S2 1x xx40 Line Scan CCD Camera 11 May 05 03 32 10091 04 www dalsa com ...
Страница 10: ...10 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Страница 38: ...38 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Страница 44: ...44 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Страница 72: ...72 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Страница 74: ...74 Spyder2 User s Manual 03 32 10091 04 DALSA ...