13
Spyder2 User’s Manual
03-32-10091-04
DALSA
Data Connector
Figure 4: MDR26 Connector
M D R 2 6 Fe m ale
1
1 4
1 3
2 6
M at in g P a r t
: 3 M 33 4 -31 se r ie s
C a b le :
3 M 1 4 X 2 6 -S Z L B -X X X -0 L C
* *
Table 2: Camera Link Base Configuration
Base Configuration
One Channel Link Chip + Camera CSerial
Communication
Camera Connector Right Angle
Frame Grabber
Channel Link
Signal
1
1
inner shield
14
14
inner shield
2
25
X0-
15
12
X0+
3
24
X1-
16
11
X1+
4
23
X2-
17
10
X2+
5
22
Xclk-
18
9
Xclk+
6
21
X3-
19
8
X3+
7
20
SerTC+
20
7
SerTC-
8
19
SerTFG-
21
6
9
18
CC1-
22
5
CC1+
10
17
CC2+
23
4
CC2-
11
16
CC3-
24
3
CC3+
12
15
CC4+
25
2
CC4-
13
13
inner shield
26
26
inner shield
Unused pairs should be terminated in 100 ohms at both ends of the cable.