Piranha4 8k Color Camera
User’s Manual
33
Teledyne DALSA
03-032-20274-00
Timed
The exposure duration time is set using the Exposure Time feature.
The exposure starts 1.5µs after EXSYNC rising edge when Trigger mode is On
The exposure starts 1.5µs after Line Start event when Trigger mode is Off.
Maximum
Internally generated, maximizing exposure time for line rate.
Exposure Time
Sets the exposure time (in microseconds) when Exposure mode is set to Timed.
Exposure Modes in Detail
1. Internally Programmable Line rate and Internally Programmable Exposure Time (Default)
Line rate is the dominant factor when adjusting the line rate or exposure time. When setting
the line rate exposure time will decrease, if necessary, to accommodate the new line rate.
When adjusting the exposure time the range is limited by the line rate.
Note
:
The camera will not set line periods shorter than the readout period.
GenICam parameters to set:
I / O Controls > Trigger Mode > Off
Sensor Control > Exposure Mode > Timed
2. Internally Programmable Line rate and Maximum Exposure Time
Line rate can be adjusted. When setting the line rate, exposure time will automatically
adjust, to accommodate the new line rate.
Note
:
The camera will not set line periods shorter than the readout period.
GenICam parameters to set:
I / O Controls > Trigger Mode > Off
Sensor Control > Exposure Mode > Maximum
3. External Line Rate, Programmable Exposure Time
In this mode, the line rate is set externally with the falling edge of EXSYNC. When the line
rate changes, exposure time may need to be decreased, to accommodate the new line rate.
When adjusting the exposure time the range is limited by the line rate.
GenICam parameters to set:
I / O Controls > Trigger Mode > On
Sensor Control > Exposure Mode > Timed
4. External Line Rate and Maximum Exposure Time
In this mode, the line rate is set externally with the falling edge of EXSYNC. When the line
rate changes, exposure time will automatically adjust, to accommodate the new line rate.
GenICam parameters to set:
I / O Controls > Trigger Mode > On
Sensor Control > Exposure Mode > Maximum
1.
External Trigger Off, Maximum exposure
Free running, not synchronized to an external signal