Piranha ES-xx User Manual
Teledyne DALSA
03-032-20070-02
99
Mnemonic
Syntax
Parameters Description
set sync frequ ency
ssf
i
Set the fram e rate to a valu e from :
TDI
ES-80-08k40: 3499.56-34305.3
ES-80-08k80: 3499.87-68610.6
ES-80-04k40: 3499.87-68610.6
ES-82-04k40: 3499.87-55020.6
ES-82-04k80: 3499.87-11111.0
Area
ES-80-08k40: 1-3084.5
ES-80-08k80: 1-6169.0
ES-80-04k40: 1-6169.0
ES-82-04k40: 1-1084.7
ES-82-04k80: 1-2080.7
Valu e rou nd ed u p / d ow n as requ ired .
Refer to
Setting Fram e Rate on p age 41 for
d etails.
set system gain
ssg
t i
Set the d igital gain.
t
= tap selection , either
1
to
number
of CCD taps
, or
0
for all tap s
i
= Digital gain in a range from
0
to
65535
. The d igital vid eo valu es are
m u ltip lied by this nu m ber. Refer to
Setting Digital Gain on p age 61 for
d etails.
stage select
stg
i
Sets the nu m ber of TDI stages.
Allow able valu es are:
16
or
32
for ES-80 models
8
or
16
for ES-82 models
Refer to 3.3.2 Selecting the N u m ber of
CCD Integration Stages for d etails.
set u p p er threshold
sut
i
The p ixels equ al to or greater than the
u p p er threshold are checked for and
rep orted in the end -of-line sequ ence in
a range from
0
-
4095
. Refer to 3.5.3
End -of-line Sequ ence for d etails.
set vid eo m od e
svm
i
Sw itch betw een norm al vid eo m od e
and test p atterns:
0
: N orm al vid eo m od e
1
: Test p attern
2
: Test p attern
3
: Test p attern
Refer to section 3.7.1 Generating a Test
Pattern for d etails.
set TDI m od e
tdi
i
Set the camera’s operating mod e.
0
: Area Mod e
1
: TDI Mod e
Refer to section 3.5.1 for d etails.
Содержание Piranha ES Series
Страница 22: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 22 ...
Страница 88: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 88 ...
Страница 102: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 102 ...
Страница 104: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 104 ...