In the follow ing exam p le, analog gain is being set for all tap s. The p eak valu e of each tap
w ithin the region of interest is calibrated to the sp ecified target valu e. All tap s com p letely
ou tsid e the region of interest are calibrated to the average analog gain valu e of the tap s
insid e the region of interest.
Figure 16: Calibrating Analog Gain for all Taps
Video
Region of Interest
V
id
e
o
0
12288
4000
9700
2800
After analog gain calibration
Before analog gain calibration
0
4095
ccg 1 0 2800
When calibrating all taps, taps completely outside the region
of interest (in this example, interleaved taps 1and 2) are calibrated to the
average analog gain of taps within the region of interest. Taps
within the region of interest calibrate to the target value. Note: Seams
between taps will be visible until you perform white light calibration using
the
command.
ccp
Pixel Number
Tap 1(odd)
Tap 2(even)
Tap 5(odd)
Tap 6(even)
Tap 7(odd)
Tap 8(even)
Tap 3(odd)
Tap 4(even)
Updating the Gain Reference
To update the analog gain reference:
Pu rp ose:
Sets the cu rrent analog gain setting to be the 0d B p oint. This is
u sefu l after tap gain m atching allow ing you to change the gain on
all tap s by the sam e am ou nt.
Syntax:
ugr
All manuals and user guides at all-guides.com
Содержание Piranha 3 P3-80-08k40-00-R
Страница 14: ...Piranha 3 User Manual 03 032 10216 06 Teledyne DALSA 14 All manuals and user guides at all guides com ...
Страница 22: ...Piranha 3 User Manual 03 032 10216 06 Teledyne DALSA 22 All manuals and user guides at all guides com ...
Страница 70: ...Piranha 3 User Manual 03 032 10216 06 Teledyne DALSA 70 All manuals and user guides at all guides com ...
Страница 74: ...Piranha 3 User Manual 03 032 10216 06 Teledyne DALSA 74 All manuals and user guides at all guides com ...
Страница 88: ...Piranha 3 User Manual 03 032 10216 06 Teledyne DALSA 88 All manuals and user guides at all guides com ...