75
Piranha2 User’s Manual
Code Command
Short
Form
Parameters Description
Parameters:
i
= integer
f
= float
t
= tap selector
s
= string
x1
= pixel start
number
x2
= pixel end number
[]=
optional
parameter
start and end values in a range
from 1 to sensor pixel count.
13
get_prnu_coeff
gpc
i
Read the PRNU coefficient.
16 get_processing_status
gps
Read the status of last
executed command and coded
value for all pending
monitoring task warnings.
17
get_sensor_serial
gss
Read the sensor serial number.
18 help
h
Display the online help.
19
region_of_interest
roi
i i
Set the pixel range for reading
end-of-line statistic and for the
region of pixels used in the
cag
,
cao
,
gl
,
gla
,
ccf
, and
ccp
commands. Pixel start and
end values in a range from 1 to
sensor pixel count.
20 reset_camera
rc
Reset the entire camera
(reboot).
21
reset_pixel_coeffs
rpc
Reset the pixel coefficients to
0.
22 restore_factory_settings
rfs
Restore the camera’s factory
settings. FPN and PRNU
coefficients reset to 0.
23
restore_user_settings
rus
Restore the camera's last saved
user settings and FPN and
PRNU coefficients.
24 set_analog_offset
sao t
i
Set the analog offset. The first
parameter is the tap selection 1
to 4, 0 for all taps. The second
parameter controls the digital
analog convertor (DAC), in a
range from 0 to 1023, that sets
analog offset. Offset increases
with higher values.
25
set_baud_rate
sbr
i
Set speed of serial
communication port. Baud
rates: 9600, 19200, 57600, and
115200. Default baud: 9600
26 set_camera_id
sci s
[s]
Set camera ID. The first
parameter is a character A to
Z, or 0 to 9. The second
optional parameter is the serial
number of the addressed
camera.