3.3 EMC Operation
The CA-D6 has been designed for EMC compliance. The test setup shown below
has been verified to the limits set in EMC standards IEC 1000-4-2; 1995, 1000-4-3;
1995, 1000-4-4; 1995, and CISPR-22.
Data Bus: 3M #3750-50, 6’ (1.8m), shielded jacketed twisted pair
User Bus: 3M #3750-9, 6’ (1.8m), shielded jacketed twisted pair
Power: 18 AWG
Data Bus: 3M #3750-50, 6’ (1.8m), shielded jacketed twisted pair
Data Bus: 3M #3750-50, 6’ (1.8m), shielded jacketed twisted pair
Follow these specific guidelines to maximize compliance in your application:
•
Keep control and data cables as short as possible.
•
Control and data cables must have 95% coverage shields that include braided
wire. Metallic foil shields are insufficient without braided wire.
•
Ensure that all cable shields have 360
°
electrical connection to the connector.