Linea ML Color Cameras
The Linea ML Color Camera
9
Environmental Specifications
Storage temperature range
-20 °C to +80 °C
Humidity (storage and operation)
15% to 85% relative, non-condensing
MTBF (mean time between failures)
> 100,000 hours, typical field operation
Flash Memory Size
Table 6: Camera Flash Memory Size
Camera
Flash memory size
All models
4 GByte
Certification & Compliance
Table 7: Camera Certification & Compliance
Compliance
See the Declaration of Conformity section at the end of this manual.
KC Registration
Verified equipment registered under the Clause 3, Article 58-2 of Radio Waves Act. ML-FC-08K10T registration no. R-R-
Td2-ML-FC-08K10T. Registration date 2018-12-28.
ML-HC-16K10T registration pending.
Figure 1: Power and Temperature*
Note:
*Measured using ML-HC-
16K10T
camera and showing ambient temperatures.
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
0
10
20
30
40
12
13
14
15
16
17
18
19
20
21
22
23
24
C
u
rr
e
n
t
(A
)
P
ow
e
r
(W
)
Voltage (V)
Camera Input Power
Power @ 65°C (W)
Power @ 25°C (W)
Camera Input Current @ 65°C (A)
Camera Input Current @ 25°C (A)
Содержание ML Series
Страница 16: ...14 The Linea ML Color Camera Linea ML Color Cameras Mechanical Drawings ML FC 08K10T 00 R ...
Страница 17: ...Linea ML Color Cameras The Linea ML Color Camera 15 ML FC 16K04T 00 R ...
Страница 18: ...16 The Linea ML Color Camera Linea ML Color Cameras ML HC 16K10T 00 R ...
Страница 30: ...28 Camera Performance and Features Linea ML Color Cameras Figure 10 Image with incorrect scan direction ...
Страница 80: ...78 Declaration of Conformity Linea ML Color Cameras Declaration of Conformity ...