68
•
Camera Performance and Features
Linea HS Series Camera User's Manual
Internal Trigger Mode
See the section Camera Control Category in Appendix A for GenICam features associated with this
section and how to use them
Related Feature:
In the different TDI Modes use the following features to set the internal trigger rate:
Standard Models
Table 27: Standard Models Internal Trigger Rate Features
TDI Mode
Trigger Rate Feature
Maximum
TDI
AcquisitionLineRate
300 kHz
HDR / HFW
AcquisitionLineRate
150 kHz
Area
AcquisitionFrameRate
2 kHz
High Speed Models
Table 28: High Speed Models Internal Trigger Rate Features
TDI Mode
Trigger Rate Feature
Maximum
TDI
AcquisitionLineRate
400 kHz
HDR / HFW
AcquisitionLineRate
200 kHz
Area
AcquisitionFrameRate
2 kHz
Multi-Area
AcquisitionFrameRate
650 kHz
Multifield Model
Table 29: Multifield Model Internal Trigger Rate Features
TDI Mode
Trigger Rate Feature
Maximum
TDI (One color)
AcquisitionLineRate
300 kHz
TDI (Two colors)
AcquisitionLineRate
150 kHz
TDI (Three colors)
AcquisitionLineRate
100 kHz
Area
AcquisitionFrameRate
2 kHz
Multi Area
AcquisitionFrameRate
650 Hz
Super Resolution 32k Model
Table 30: Super Resolution Model Internal Trigger Rate Features
TDI Mode
Trigger Rate Feature
Maximum
32k Modes
AcquisitionLineRate
150 kHz
16k TDI
AcquisitionLineRate
300 kHz
Area
AcquisitionFrameRate
2 kHz
Multi Area
AcquisitionFrameRate
650 Hz