DALSA
Falcon XDR and HG Series Camera User's Manual
72
Troubleshooting
Data Clocking/Output Signals
To validate cable integrity, have the camera send out a test pattern and verify it is being properly
received. Refer to section 3.11 Generating a Test Pattern for further information on running test patterns.
5.2
Troubleshooting Using the Serial Interface
5.2.1 Communications
To quickly verify serial communications send the
h
(help) command. By sending the
h
and receiving the
help menu, the serial communications are verified. If further problems persist, review Appendix B for
more information on communications.
5.2.2 Verify
Parameters
To verify the camera setup, send the
gcp
(get camera parameters) command. To retrieve valid
parameter ranges, send the
h
(help) command.
5.2.3
Verify Factory Calibrated Settings
To restore the camera’s factory settings send the
rfs
command.
After executing this command send the
gcp
command to verify the factory settings.
5.2.4
Verify Timing and Digital Video Path
Use the test pattern feature to verify the proper timing and connections between the camera and the
frame grabber and verify the proper output along the digital processing chain.
Содержание Falcon 1.4M100 HG Monochrome
Страница 18: ...DALSA Falcon XDR and HG Series Camera User s Manual 18 Introduction to the Falcon XDR and HG Cameras ...
Страница 28: ...DALSA Falcon XDR and HG Series Camera User s Manual 28 Camera Hardware Interface ...
Страница 70: ...DALSA Falcon XDR and HG Series Camera User s Manual 70 Optical and Mechanical Considerations ...
Страница 74: ...DALSA Falcon XDR and HG Series Camera User s Manual 74 Troubleshooting ...
Страница 90: ...DALSA Falcon XDR and HG Series Camera User s Manual 90 Appendix C EMC Declaration ...
Страница 92: ...DALSA Falcon XDR and HG Series Camera User s Manual 92 Technical Support ...
Страница 95: ...Falcon XDR and HG Series Camera User s Manual DALSA Index 95 serial interface 72 V video data 76 ...