6M18 Camera User’s Manual
7
DALSA
03-32-10017-03
Cluster defect
•
A grouping of pixel defects where within a sub area of 3*3 pixels there are at most 5 present.
Column or row defect
•
A column or row which has more than 12 pixel defects.
•
Column defects must be horizontally separated by 3 columns.
•
Row defects are not allowed.
1.3 Camera Performance Specifications
Table 3: 6M18 Camera Performance Specifications
Physical
Characteristics
Units
Notes
Resolution
H x V pixels
3072x2048
Pixel Size
µm
12x12
Chip Working Area
mm
36.86 x 24.57
Pixel Fill Factor
%
100
Image Sensor Grade
Industrial Grade
See Table 2:
Sensor Cosmetic
Specifications
Size
mm
146x92x105
Mass
kg
1.05
Power Dissipation
W
< 27
Output Data Format
LVDS
4 x 12 Bit, LVDS
1
Serial Port Setup
9600 8N1
Serial Data Format
Hexadecimal
Lens Mount
F-mount
and M72x1mm
Cooling Fan
Present
Operating Ranges
Units
Min.
Max.
Data Rate
MHz
4 x 40
4 x 40
Operating Temp
°C
10
40
+15 Input Voltage
V
+14.25
+15.75
+5 Input Voltage
V
+4.975
+5.25
-5 Input Voltage
V
- 4.75
- 5.25
Nominal Gain Range
X
1x
10x
Binning Modes
Default
Min
Max
Horizontal Binning
1x
2x
4x
Vertical Binning
1x
2x
4x