6M18 Camera User’s Manual
23
DALSA
03-32-10017-03
3.3 Control Register Reference
A number of functions and modes depend on the control register settings. These settings are
detailed in the following sections.
The “Write Control Register” command is used to write a register that controls specific camera
triggering and test functions. This command must be followed by a data byte with bits defined as
shown in the following table.
The “Read Control Register” command allows interrogation of the camera to determine current
configuration of the control register.
Table 15: Control Register Bit Definitions
Register
Write
Command
Read
Command
Bit
Function
Default
Reset
80h
NA
7:0
Resets all registers to
default values
NA
Camera
Type
NA
C3h
7:0
Read camera type
4Dh
Firmware
Rev
NA
C5h
7:0
Read firmware
revision
Fxh
7
Integration Mode
0=Internal
1=External
0
6:4
Always 0
00
3
Trigger Mode
0=Internal
1=External
0
2
Flush Before
Integrate
0 = Charge is flushed
between frames
1 = Flushing disabled
(bit [7] must =1)
0
1
Always 0
0
Register 1
82h
C2h
0
Serial Syn Bit
0