dallmeier PVS IV Скачать руководство пользователя страница 6

6

Dallmeier electronic

PView  Station  PVS  IV

2  Safety instructions

Only use this unit if it is technically in proper working order, to the intended purpose and 

while keeping safety and potential dangers in mind. Have malfunctions or damages elimi-

nated immediately!

Appoint a professional

Installation, mounting, connection, start-up and configuration of the unit may only be carried 

out by trained and authorized professionals (installers). 

Unless otherwise expressly specified, this also applies to the maintenance, testing and repair. 

In doing so the regulations of the 

DIN VDE 0701

 series of standards (repair, modification 

and inspection of electrical appliances) must be followed in addition.

System security

In  order  to  provide  best  compatibility  and  integratability  the  system  is  delivered  without 

separate software for protection against malware or data loss. Take appropriate measures 

for malware protection. Regularly make backups to avoid data loss. Dallmeier electronic 

accepts no liability for damage caused by insufficient system security.

Read and pay attention to the documents

Carefully and completely read the documents included in delivery. Always pay attention to 

the provided instructions, notes and warnings.

Regulations surveillance systems

The use of video and audio surveillance systems is strictly regulated in most countries. 

Therefore, inform yourself on laws and regulations that govern individual applications be-

fore using the unit. Ensure compliance with these laws and regulations and also observe 

regulations regarding data, working and environmental protection.

Regulations data protection

This unit can store data that may be subject to data protection. The collecting, recording, 

processing or disclosure of such data may be forbidden and thus have legal consequences. 

Therefore, inform yourself on data protection laws and regulations that govern individual 

applications before using the unit. Ensure compliance with this laws and regulations.

Do not make modifications

Do not make any modifications to the unit (neither to the software nor the hardware) without 

consulting Dallmeier electronic. Improper modifications can cause malfunctions or damages. 

Dallmeier electronic accepts no liability for damages resulting from unauthorized or improper 

modifications to the unit.

Protection against condensation water

If the unit is brought from a cold to a warm environment, condensation water can form inside 

the unit. Short-circuits may then lead to damage to the system. Wait up to 8 hours for the 

unit to reach room temperature before starting it up.

Содержание PVS IV

Страница 1: ...1 Dallmeier electronic PView Station PVS IV Rev 1 0 0 080528 English Workstation PVS IV Installation and Configuration...

Страница 2: ...er accepts no liability for damage to property or pecuniary damages arising due to minor defects of the product or documentation e g print or spelling errors and for those not caused by intention or g...

Страница 3: ...Certifications 9 4 Installation and mounting 10 4 1 Requirements at the installation site 10 4 3 Installation in a 19 standard rack 11 5 Views and connection assignment 12 5 1 Front view 12 5 2 Connec...

Страница 4: ...configuration of the device General notes on the product and technical data are additionally provided The target audience is exclusively specially trained and authorized professionals instal lers 1 3...

Страница 5: ...rect configurations or incorrect actions NOTE ANOTE offers information on principles special features and efficient procedure as well as general recommendations Expression Expressions in bold and ital...

Страница 6: ...ded instructions notes and warnings Regulations surveillance systems The use of video and audio surveillance systems is strictly regulated in most countries Therefore inform yourself on laws and regul...

Страница 7: ...responsible for your area Do not move while in operation Strong vibrations can cause damage to the unit in particular to the hard disk s Therefore do not bump the unit or move it in a jerky motion wh...

Страница 8: ...ntation PVS IV Installation und Konfiguration CD inclusive software documentations The scope of delivery may differ depending on the ordered equipment or device variant The device s range of functions...

Страница 9: ...es The PView Station PVS IV is especially characterised by the following functions and pro perties l Operating system Windows XP l DVD R RW writer l 1000 Mbit LAN interface l HDD capacity min 160 GB l...

Страница 10: ...direct sunlight l with unsuitable ambient temperatures see technical data l near sources of strong radiation i e X rays radio transmitters or magnetic fields l with corrosive surroundings e g gases o...

Страница 11: ...he bracket 2 Pay attention to the case feet that must fit into the notches A 3 Screw together bracket and case from the underside with 3 screws see fig 4 2 1 to 3 4 Mount the PVS IV into the 19 standa...

Страница 12: ...PView Station PVS IV 5 Views and connection assignment 5 1 Front view 1 Panel Filter pad 2 Power LED Lights whenever the device is switched on 3 Status LEDs inactive 4 USB 2 0 interface 5 Panel DVD d...

Страница 13: ...e This output will be activated as M1 in case of a PVS IV version without additional VGA card 6 2 x RJ45 inactive 7 2 x USB 2 0 8 LAN port RJ45 9 Mic IN red 10 Line OUT green 11 Line IN blue 12 M4 DVI...

Страница 14: ...itor have to be connected accordingly to M3 and M4 Variant 1 standard with graphics card l M1 and M2 breakout cable are active l M3 and M4 main board are inactive Variant 2 all four monitor connection...

Страница 15: ...esting to enter the serial number will be displayed when the Dallmeier software is starting if the licence dongle is not connected accurately If the dialog to enter the serial number is displayed proc...

Страница 16: ...NOTE Note the documentation of the operating system and peripheral devices 7 2 Monitors Open the desktop context menu by right clicking on the desktop Select Properties Select the Settings tab in the...

Страница 17: ...ut M1 1 M2 2 M3 3 M4 4 see figure 7 2 To configure other monitors proceed analog as above 7 3 Software The PView PGuard and SmartGUI software is already installed on the PVS IV It finally has to be co...

Страница 18: ...er changes is dependent upon the installa tion site and the degree of soiling associated with it In normal office rooms checking every three months is generally suffici ent while a monthly check would...

Страница 19: ...ard 1 x 3 5 Exchangeable hard disks optional 1 x 3 5 Internal hard disk optional 1 x 3 5 Max storage capacity 3 x 750 GB Interfaces Video OUT 1 x VGA 1 x DVI Audio Line IN 1 x Audio Line OUT 1 x MIC I...

Страница 20: ...20 Dallmeier electronic PView Station PVS IV 9 2 Technichal drawing Unit mm Fig 9 1 130 with feet...

Страница 21: ...any is responsible for this declaration Dallmeier electronic GmbH Co KG Cranachweg 1 D 93051 Regensburg The measurements were carried out in accredited laboratories For the evaluation of above mention...

Отзывы: