![background image](http://html1.mh-extra.com/html/dallmeier/panomera-8s/panomera-8s_commissioning_504333012.webp)
12
www.dallmeier.com
S5-S8
Commissioning
6 Requirements
6.1 Ambient Conditions
The device is designed for both indoor and outdoor use.
Unfavorable local conditions may shorten the lifetime of the product and may cause malfunctions or damages.
➡
Do not install/operate the device in places
•
with a large amount of dust and dirt,
•
with steam or oil vapors (e.g. kitchen),
•
with direct sunlight,
•
with strong heat emissions (e.g. radiator),
•
with improper ambient temperatures,
•
near sources with strong radiation (e.g. radio transmitters, magnetic fields),
•
with corrosive surroundings (e.g. gases, salt water),
•
with insufficient air ventilation (e.g. closed cabinet).
Environmental Conditions
Suitable installation sites
Indoor/Outdoor
Operating temperature
−40 °C to +50 °C (minimum start-up temperature: −30 °C)
Heater On: < +10 °C
Heater Off: > +10 °C
−40 °F to 122 °F (minimum start-up temperature: −22 °F)
Heater On: < 50 °F
Heater Off: > 50 °F
Relative humidity
0 % – 90 % RH, non-condensing
IP rating
IP66
Содержание Panomera 8S
Страница 1: ...English Commissioning 005110 1 0 3 2015 09 15 S5 S8...
Страница 18: ...18 www dallmeier com S5 S8 Commissioning 2 Slotted pan head screw with shoulder DIN 923 M6 4...
Страница 24: ...24 www dallmeier com S5 S8 Commissioning...
Страница 25: ...www dallmeier com 25 Commissioning S5 S8 Carefully remove the sun shield from the housing...
Страница 27: ...www dallmeier com 27 Commissioning S5 S8...
Страница 29: ...www dallmeier com 29 Commissioning S5 S8 Remove the plastic rails from the housing...
Страница 30: ...30 www dallmeier com S5 S8 Commissioning...
Страница 31: ...www dallmeier com 31 Commissioning S5 S8 2 Slotted pan head screw with shoulder DIN 923 M6 4...
Страница 36: ...36 www dallmeier com S5 S8 Commissioning 10 Connections Earthing grounding connection connecting thread M6...
Страница 43: ...Notes...