Rev. 1.0.0 | © 2019 Dallmeier | www.dallmeier.com
43
Commissioning MDF5450HD-DN
In order to comply with UL’s requirements, only use a UL certified “Limited Power Source (LPS)” power supply unit when
powering the device by an external DC power supply unit.
24 V DC Power IN
Weidmüller male connector SL 3.50/02/90G
(mating connector: Weidmüller plug-in connector BL 3.50/02/180 SN)
Power IN
NOTICE
Damage to the device due to improper power supply
Damage to electronic components or serious malfunctions
➡
Always ensure the correct polarity when connecting an external DC power supply unit.
➡
Do not operate the device with Power over Ethernet (PoE) if the device is powered by an external DC power supply unit.
Power IN +
Power IN −