background image

Dallmeier electronic GmbH & Co.KG

15

3

Description

3.1

Intended use

The DMS/DLS is used to record and evaluate video pictures. Up to
24 cameras can be connected. The DMS/DLS can be operated on
a network.

3.2

Performance features

The DMS/DLS is a high-resolution digital security recording system
with up to 24 camera inputs and is excellently suitable for complex
video surveillance systems (e.g. industry) at which several recording
systems are operated in a network, a central evaluation station
(Pview station) is provided and a connection to external data sources
and/or higher-level management systems is desired.

Movement detection is integrated for all the camera inputs. The
SmartFinder – a system for intelligent searching for objects in a
picture – allows rapid and efficient analysis of the recorded data in
predefined picture areas.

The detachable BNC terminal board and the LCD display for service
and status displays allow simple handling of the system.

The SEDOR technology guarantees additional security through
automatic camera tampering recognition (focus change, turning,
covering and spray painting).

Extensive monitoring mechanisms (dynamic fan controller, external
and internal temperature monitoring, module diagnostics, voltage
monitoring, etc.) ensure maximum operating stability and durability
of the recorder.

3.3

Interfaces

The integrated Ethernet interface allows full connection on existing
networks. The USB interface on the front offers a simple option for
connecting external media for backup.

See the "Installation and Configuration" document for a detailed
description of the interfaces.

Содержание DMS 180 III Enterprise

Страница 1: ...Dallmeier electronic GmbH Co KG 1 Operating Instructions Digital HD Recorders DMS 180 III DMS 180 III Enterprise DLS 6 S1 DLS 24 S1 DK 124 000 EN Rev 4 1 0 070405 English ...

Страница 2: ...rst receiving written permission from Dallmeier electronic GmbH Co KG We reserve the right to make technical modifications The manufacturer accepts no liability for damage to property or pecuniary damages arising due to minor defects of the product or documentation e g print or spelling errors and for those not caused by intention or gross neglegence of the manufacturer Dallmeier electronic GmbH C...

Страница 3: ...orced ventilation 20 3 8 3 Temperature monitoring 20 3 8 4 Tamper protection 22 3 8 5 Quiescent current monitoring 22 3 9 Certifications 23 3 10 Warranty 23 4 Live mode 25 4 1 Selection of a live split 26 4 2 Sequencer operation 26 4 3 Direct switching to a camera picture 26 5 Playback mode 27 5 1 Select track 28 5 2 Camera filters 29 5 3 Operating panel for playback 31 5 3 1 Displaying the large ...

Страница 4: ...7 2 6 Exporting picture sequence to video tape 59 7 3 Importing exported pictures 60 8 Controlling a camera 63 8 1 Functions for camera control 63 8 2 Saving and calling up camera positions 64 8 3 Assigning position names 64 9 UTC zoom control 65 10 Erasing and releasing tracks 69 10 1 Normal erasing of a recording 69 10 2 Releasing erasing saved single tracks 69 10 3 Releasing ring and reference ...

Страница 5: ...ng plug in 88 15 2 2 Viewing recorder pictures 89 15 2 3 Ending picture viewing via browser 92 15 3 Picture evaluation DMS WebAccess 92 15 3 1 Compatibility 92 15 3 2 Starting WebAccess 93 15 3 3 Evaluation of the recorder pictures 93 16 Info menu 95 17 Switching unit off 97 18 Maintaining the unit 99 18 1 Changing the filter mat 99 18 2 Cleaning the unit 100 19 Troubleshooting 101 ...

Страница 6: ...Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS 6 ...

Страница 7: ...s this document The Operating Instructions describe the operation of the device This includes for example controlling cameras setting the screen view in Live mode searching for saved pictures and playback importing exporting pictures and changing the filter pad The target audience of this document is the operator Experience using a computer mouse is required No special technical knowledge is requi...

Страница 8: ...d formats are used to maintain the clarity of the document DANGER The warning word DANGER denotes an immedi ate danger that may cause death or serious injury if it is not averted WARNING The warning word WARNING denotes a possible danger that may cause death or serious injury if it is not averted CAUTION The warning word CAUTION denotes a possible danger that may cause minor injury if it is not av...

Страница 9: ...Dallmeier electronic GmbH Co KG 9 Expressions Expressions in bold and italics generally indicate a control element on the device switches or labels or on its user interface buttons menu entries ...

Страница 10: ...Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS 10 ...

Страница 11: ... regulated in most countries Therefore inform yourself on laws and regulations that govern individual applications before using the unit Ensure compliance with these laws and regulations and also observe regulations regarding data working and environmental protection Regulations data protection This unit can store data that may be subject to data protection The collecting recording processing or d...

Страница 12: ...a requirements at the installation site and if applicable maintenance regulations Expansion components peripheral devices Use only expansion components conforming with the technical data of the unit Inappropriate peripheral devices may result in the violation of local laws and regulations and damages to the unit Furthermore the use of peripheral devices that are not certified by Dallmeier electron...

Страница 13: ...the sales partner responsible for your area Measures to be taken in the event of damage and burnt smell If you notice burnt smell or formation of smoke from an unit immediately disconnect it from the power supply pull out the po wer plug Please contact the sales partner responsible for your area Disposal Disconnect the unit from the power supply Remove all connected units and system components Ret...

Страница 14: ...Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS 14 ...

Страница 15: ...or intelligent searching for objects in a picture allows rapid and efficient analysis of the recorded data in predefined picture areas The detachable BNC terminal board and the LCD display for service and status displays allow simple handling of the system The SEDOR technology guarantees additional security through automatic camera tampering recognition focus change turning covering and spray pain...

Страница 16: ...tes a hardware problem e g hard disk fault or camera failure In normal operation the display shows the serial number of the system the software version the internal and external temperature and the model name of the recorder e g DMS 180 III With some malfunctions you also receive information on possible sources of the fault on the display 3 5 Filter pad A filter mat is positioned behind the front ...

Страница 17: ...es Tracks all all Track 1 by 11 Standard Reference Wavelet card 2 way 4 way Equipment Unit type DMS 180 III DMS 180 III Enterprise Pro Video inputs maximum 24 24 Enabled video inputs 6 12 System parameters Gas station Bank Ind all Industry Field recording Frame recording yes yes yes yes Tracks all Track 1 Track 1 by 11 Standard Reference Reference Wavelet card 4 way 8 12 way OnBoard VGA connection...

Страница 18: ...the description The following table provides an overview of the track names Equipment Unit type DLS 6 S1 DLS 24 S1 OnBoard VGA connection SCD 25 yes no Splitter card MCD 25 optional yes Combination drive optional optional LAN yes yes ISDN optional optional SCSI optional optional USB 2 0 yes yes Browser yes yes Track names Track type Name Industry Bank Tank Long play track 1 A Track 1 Suspicion Car...

Страница 19: ...mains voltage is available again the DMS DLS automatically starts up again The duration of the failure does not play a role here A minor disadvantage of the long bridge duration is the fact that you must wait at least 10 seconds after switching off the system before you can switch it on again The reason for this is the discharge time of the bridging electrolytic capacitor After normal switch off o...

Страница 20: ...llation site Always ensure proper ventilation Ensure that the ventilation slits of the DMS DLS are located at least 4 inch from other objects or to a cabinet wall 3 8 3 Temperature monitoring The DMS DLS has three temperature sensors for temperature monitoring The sensor for measuring the outside temperature is found at the back on the connection plate Another sensor measures the internal temperat...

Страница 21: ...ed ambient temperature due to sunshine of 131 F without incurring damage This corresponds to Environment Class II VdS 2110 Fan controller To keep bothersome noise of the fans to a minimum the DMS DLS features a fan controller which regulates the fans depending on the external internal and CPU temperatures This is why there is less bothersome noise in well ventilated rooms especially in air conditi...

Страница 22: ...t current monitoring An external device can be connected to the OUT contact This is usually a burglar alarm The burglar alarm has a specific quiescent current depending on the model If it is interrupted or changed the burglar alarm emits a signal The recorder can be configured so that the burglar alarm responds when z the recorder is switched off z the cable is disconnected z the cable is manipula...

Страница 23: ...t Prevention Regulation banks BG Test Certificate 973001 only system parameter bank VdS Registration No V 102001 only DMS 180 III Power network approvals in accordance with IZB DVS FIDUCIA UL USA NWGQ E219273 UL Canada NWGQ7 E219273 MABISZ Hungaria C TICK FCC CB DK 4624 Kalagate CE 3 10 Warranty The warranty period is 36 months The terms and conditions valid at the signing of the contract apply ...

Страница 24: ...Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS 24 ...

Страница 25: ... the split window can differ The following functions are available to the user in Live mode without having to enter a password z Selection of a live split z Direct selection of a camera z Switch to sequencer operation If you click once with the right hand mouse button the pop up menu for the live mode is displayed Fig 4 1 A B Fig 4 2 Pop up menu at a system with MCD 25 C Fig 4 3 Pop up menu at a s...

Страница 26: ...ra switching on a split window click the Sequencer button B The cameras seen with camera switching are set in the Sequencer dialog 4 3 Direct switching to a camera picture To purposely switch the picture of a camera click the button with the corresponding camera name C NOTE To see camera switching both with the sequencer as well as with direct switching to a camera picture a split window of the se...

Страница 27: ...ut is made or the mouse is not moved within a period of 10 minutes in Playback mode the system automatically switches to Live mode for security reasons unauthorized use You are now in the Main menu with the respective Live pictures but not yet in Playback mode To reach Playback mode you must first select a track Fig 5 1 Dialog selection Split type selection Information window Operating panel ...

Страница 28: ... The camera specific single tracks are displayed on the Standard Tracks tab If you have not entered any camera names only the camera number appears e g 1 for individual track of camera 1 If for example an alarm already caused camera specific single tracks standard tracks to be saved these tracks are listed in the Saved Tracks tab with the time and date of saving Click on Update to show all current...

Страница 29: ...ding on one of these tracks can be seen first in Playback mode In the operating panel for playback the buttons of these cameras appear as pressed green and thus activated for playback To play back the pictures of just one camera all other cameras must be deactivated for the playback The button of the deselected camera s gets an orange background You can activate and deactivate the individual camer...

Страница 30: ...vate all cameras except this Except for the selected camera all cameras are now deactivated for playback orange button color Naturally you can also activate other cameras for playback later on Activating all cameras for playback In contrast to single camera selection you can activate all cameras via the selection dialog Move the cursor to a camera button and click the right mouse button Now select...

Страница 31: ... track 6 Database for playback 7 Beginning of track 8 High speed rewind 9 Rewind 10 Picture by picture rewind 11 Stop pause 12 Picture by picture fastforward 13 Fast forward 14 High speed fast forward 15 End of track 16 Search function filter 17 Zoom 18 Exit Playback mode The buttons in the operating panel have the following meaning Fig 5 10 NOTE If the playback is stopped you can change the curre...

Страница 32: ...isplays the recorder and camera description if they have been entered explicitly for the respective camera 5 3 2 Displaying the large information window manually Irrespective of the controller for quick picture search you can also display the large information window manually Click on the information window in the control panel B for this purpose 5 3 3 Hiding the large information window If you wa...

Страница 33: ...an be adjusted to your needs The speed decreases as you move the slider knob downward If you change the playback direction e g from playback forward to playback rewind the speed previously set is retained NOTE During playback you can change the playback speed using the mouse wheel as long as the mouse pointer is in the control panel NOTE In certain circumstances you can improve the playback by swi...

Страница 34: ... the track The date and time of the respective point recorded picture can be read in the information window The oldest picture is found at the left end of the slider knob and the newest picture is at the right end 5 6 Playback of full pictures The button shown in the control panel see Fig 5 15 allows to check whether the displayed images were saved in frame mode NOTE The button for selection of th...

Страница 35: ...yback mode However you can define whether recording is to be interrupted during playback IMPORTANT Beware of accidental overwriting of recordings especially at high recording speeds As the ring memory method involves constant overwriting of the oldest pictures while recording pictures which you would like to evaluate could potentially be lost If moving complete picture sequences to an external dat...

Страница 36: ...ure are now inactive A magnifying glass symbol is displayed on the split window Monitor Split P A section enlargement is displayed in the Monitor Split P when you press the left mouse button The position of the displayed magnifying glass before zooming corresponds to the center of the enlarged section as far as possible The enlargement is increased with every further click A maximum of 4 steps enl...

Страница 37: ...ure or parts of it zoom by clicking on Print picture to a printer connected to the DMS DLS Select the desired picture for example via a search function Click Print picture Your picture is output to the printer that was specified as the Stan dard printer on the Printer dialog Special information from the picture header such as the date time camera etc are printed out separately from the picture NOT...

Страница 38: ...e video picture before printing In order to display and hide the additional information click with the right mouse button on the Pause button in the operating panel This information is generally displayed during a live picture so that it is also contained on a video print of the live picture 5 10 Live picture feeding to the Monitor Split P The larger split window always has Monitor Split P assigne...

Страница 39: ... small split window the corresponding camera is fed immediately to the Monitor Split P large split window A bright border around the monitor split indicates that you have fed a camera picture by means of this method NOTE If the live picture of a small split window was fed to Monitor Split P it is not possible to subsequently change the camera over via the operating panel The feed remains active un...

Страница 40: ...Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS 40 ...

Страница 41: ...tion z Simple search Picture search by date and time z Quick search Picture search by time intervals z Indexsearch Picture search by events z Extended search Picture search by for example account or transaction number z SmartFinder Search for objects in a picture only active in case of a corresponding configuration in the Camera settings dialog To select the desired search function click the corre...

Страница 42: ...ime intervals With the quick search time intervals are searched The intervals can be set by day hour minute and second in steps of 1 5 10 or 30 Before calling up the search function and searching in time intervals please set a starting point for the quick search with the slider knob in Playback mode see Quick picture search You can also use the simple search by date and time here The corresponding...

Страница 43: ...efore calling up the search function and starting the index search please set a starting point for the quick search with the slider knob in Playback mode see Quick picture search You can also use the simple search by date and time here The corresponding picture is now the starting point for the index search Click the Search functions button and select the Index Search tab Then click the Events but...

Страница 44: ...ded search The extended search is used when other data in addition to the picture data including date and time is saved for the picture This is especially the case with ATMs and cash registers NOTE The search criteria available in this search function are set by the configuration in the Search Items dialog box The extended search is performed within a time window You define the time window with th...

Страница 45: ...ou can define 3 other search criteria which make the search more refined This could be another specific amount of money or currency type for example Start searching by clicking Start 6 5 SmartFinder With the SmartFinder search function you can search for changes in any picture area Certain requirements have to be fulfilled for this search function 1 The corresponding camera has to be activated for...

Страница 46: ...TE The camera whose picture is currently displayed in the playback will be used for the search 6 5 1 Basic procedure Steps A to D first show the basic course of the search function Further settings can be found in the Advanced search options section A Selecting the search range in the picture Click the Set button Drag a rectangle in the picture by using the mouse This rectangle marks the range in ...

Страница 47: ...nd Stop are used to set the time frames time window for the search The procedure is identical to the description in the Advanced search section C Starting a search Click the Search button to start the search process The results of the search hits are displayed in an event list see Fig 6 9 The display Hit x y shows the number of hits found under y and the number of the hit currently selected under ...

Страница 48: ...nfluenced by means of the settings in the Advanced Search Op tions dialog Click the Options button Picture changes are generally displayed as rectangular fields You can specify in the Draw Mode section whether the display is to be realized as individual fields or as a combination of fields In the Search Mode a relationship is established between these rectangles picture changes and the marking dra...

Страница 49: ...not activated Rectangle in the draw mode adjacent and overlapping rectangles are combined into a single area Intersection If you have activated Intersection in the draw mode only those rectangles are displayed that are linked correspondingly with the marking drawn by you depending on the search method see Search mode If you have not activated Interface all the rectangles are displayed Fig 6 11 Rec...

Страница 50: ...d If Balance Point Search is activated a hit is always listed when this geometric balance point lies within the marking drawn by you Intersection Search If Intersection Search is activated you already obtain a search result when a rectangle of a figure change intersects the marking drawn by you by even the smallest amount The geometric balance point is not of relevance then Fig 6 15 Balance point ...

Страница 51: ...led Instal lation and configuration you can decide whether the recording should be made using the database DB If the track is activated with database recording for playback and search the DB will generally be active One exception to this rule is if a track has at least one permanently recording camera Click on the DB button to toggle between Use DB and Do not use DB Use DB Do not use DB Whether it...

Страница 52: ...z Few cameras selected for playback z Use of the DB beneficial Track with z Several cameras z Recording gaps picture comparison recording mode z All cameras filtered for playback z Use of the DB not beneficial Track with z Several cameras z At least once camera recording permanently z Use of the DB not beneficial DB is automatically deactivated disabled ...

Страница 53: ...s 7 2 Export pictures and sequences 7 2 1 Export pictures To export pictures to external storage media search for the required picture in the selected track using the Slide A Click on Export pictures B Click on Add picture The Export option is inactive until you have selected the first picture If you wish to export more pictures from this track simply repeat the steps described above When you have...

Страница 54: ...rt using the slide Click on Export pictures B Click on End of sequence If you wish to export more sequences repeat the steps described above 7 2 3 Export list When you click on Export the export list will open This list contains all the pictures and sequences you have selected for export Fig 7 3 NOTE The export list contains the pictures from the currently selected track and camera If you change t...

Страница 55: ...ion as a sequence The selection of the export list can be exported in the form of a sequence In other words all the files pictures and sequences on the list can be merged to form a single sequence You can change the order by clicking on the various column headings Check the checkbox Export as sequence Click on the keyboard symbol Enter the name of the sequence using a connected keyboard or the mou...

Страница 56: ...list Select a device from the pull down menu After selecting the device its current information will be shown Compare the Export information with the free memory of your selected medium If necessary delete some data from your medium To do this mark the appropriate file in the information window and click on NOTE In case of a CD RW the whole CD must be deleted It is not possible to delete individua...

Страница 57: ... on to save the files or Click on to return to the export list or Click on to cancel the process and exit the export menu Special feature for burning CD ROM s If you wish to backup your pictures and sequences to a CD ROM you can decide whether you wish to create individual sessions or a finalized CD Multi session procedure Leave the checkbox Finalize CD unchecked to allow further burning sessions ...

Страница 58: ... progress window will open Check the checkbox Show export s log file to view information about the saving procedure Also check the checkbox Detailed message to view more detailed information about the saving procedure After the export has finished click on to exist the export menu or click on to return to the previous export menu Fig 7 6 ...

Страница 59: ...ugh output of the monitor connected to M1 of the DMS DLS and connected properly NOTE Monitor output 2 of the DMS DLS can only be used if the field Monitor 2 as Monitor 1 in the Sequencer dialog Setup System Display Monitor Sequencer is selected see document entitled Installation and Configuration Chap Setting Sequencer Open the track with the desired recording Search for the starting point of play...

Страница 60: ...port imaging viewing on DMS DLS Pictures exported using the export function can be read back in at the DMS DLS and viewed This does not include backups on video tape however IMPORTANT Pictures already processed can no longer be read in and viewed on the system Exported pictures cannot be saved to the hard disk of the DMS DLS with the Import function Click Import in the dialog selection Fig 7 7 ...

Страница 61: ...selecting the device its current information will be shown Select the required file Click on to load the file into the recorder All playback functions are available for evaluation of the recording Erasing files The Erase function is also available in the Import dialog Individu al recording files can be erased from a floppy disk as described in the Export chapter With CD RWs only the entire CD can ...

Страница 62: ...Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS 62 ...

Страница 63: ... be controlled 8 1 Functions for camera control If you click the active Control function button the operating panel for camera control appears The functions are as follows 1 Focus minus 3 Aperture open 2 Focus plus 4 Aperture closed 5 and 6 Zoom in out Clicking the directional arrows controls the camera up down left and right Clicking the center button with the crosshairs moves the camera to the s...

Страница 64: ...ting Select Save Position and click with the left mouse button To call up a specific position click the respective position number with the left mouse button The camera now automatically moves to the position set under this number 8 3 Assigning position names To more easily identify the saved camera positions you can enter a name instead of the number Right click the position button to which you w...

Страница 65: ...n 5 Position query 2 Zoom out 6 Preset 1 to 3 3 Zoom control 7 Menü on off 4 Preview window 8 Reset settings NOTE Points 6 8 can be used to have a direct influence on the internal configuration of a Dallmeier electronic UTC camera It is not generally necessary to make any changes to this configuration This functionality is described in the documentation entitled Installation and configuration 1 2 ...

Страница 66: ...the camera menu The procedure is described in the manual entitled In stallation and configuration By clicking on Zoom in 1 you can reduce a picture section in 11 stages in digital form Clicking on Zoom out 2 increases the size of the picture section The position of the section in the full picture is displayed in the preview window with a border If the mouse pointer is inside the rectangle you can ...

Страница 67: ...Go to one of the buttons with the mouse pointer and right click on it Select Save position Enter name for position Right click again on the button under which you have saved the position Select Change name Enter a name for the position That you saved previously You can fix up to eight picture sections for each camera By clicking on one of the buttons you can select the appropriate section directly...

Страница 68: ...68 Digital HD Recorders DMS DLS Dallmeier electronic GmbH Co KG ...

Страница 69: ...pictures or picture sequences to an external medium see chapter Exporting pictures Exporting 10 1 Normal erasing of a recording In normal operation you can erase the recording on each indivi dual track This normal erasing is possible for all types of tracks ring track single track and reference track Open the track on which you want to erase the pictures Klick the Erase track button in the operati...

Страница 70: ...track that you want to use for further recording Click the Delete button that is now activated In the case of several single tracks you can also mark these together and release erase them Click with the left mouse button and keep it pressed Now move the cursor downwards in order to mark further saved tracks If you click Delete all the marked tracks are deleted In order to deselect a marking click ...

Страница 71: ... are usually still available for recording after single tracks have been saved depending on the set number of single tracks further recording is not possible at saved ring tracks and at the reference track NOTE In contrast to the single tracks the pictures on the ring tracks are not erased during releasing During further recording the respectively oldest pictures are overwritten Click the Open tra...

Страница 72: ...Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS 72 ...

Страница 73: ... are called the reference picture set IMPORTANT If the reference picture memory is set up all previously recorded pictures are erased The hard disk must be restructured due to the additional memory Important pictures should therefore be transferred to a different storage medium beforehand see chapter Exporting pictures 11 1 Creating a new reference picture set A reference picture set can only be c...

Страница 74: ... the virtual keyboard After confirming your input with OK the date time and name which has just been assigned appear in the Memory Selection field The pictures of the camera connected at this time appear in the Preview field at the same time 11 2 Comparison of reference to live picture Select the picture of a camera from the reference picture set by clicking the arrow buttons Fig 11 2 Fig 11 3 ...

Страница 75: ...idual picture sets to view In the Memory Selection field select the picture set you would like to view and compare with current live pictures Then click View The pictures of the corresponding picture set are displayed Selection and comparison occur as described 11 4 Deleting a reference picture set As the amount of storage of the reference picture memory is limited the oldest reference picture set...

Страница 76: ...Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS 76 ...

Страница 77: ... configuration of the assistant mode and the permissions defined in the user management Grey dialogs in the assistant mode are deactivated for the respective user group NOTE Activation and configuration of the assistant mode is carried out by the administrator see the Instal lation and Configuration document Click the Setup button to open the assistant mode Click on to leave the current dialog and...

Страница 78: ...rder DMS DLS Clicking the Info button causes the information dialog to be shown see section Info menu Clicking the System Messages button causes this dialog to be directly shown see section Archive of system messages Click on to close the assistant mode ...

Страница 79: ...ave arisen click Setup System System Messages 13 1 Displaying all system messages First of all use the pull down menu next to Apply to decide which category of system messages you wish to display Standard System messages relating to certain states of the recorder or events for example camera failure recorder restart etc will be displayed Protocol System logons and logoffs will be displayed includi...

Страница 80: ...System messages dialog by clicking on 13 2 Filtering system messages System messages in various categories can be listed in filtered form by clicking on the appropriate symbol button Fig 13 2 System messages Cover contact messages Logins of other user Camera failures or Recorder configuration Ventilation problems SEDOR messages Changes system configuration Changes interface configuration Database ...

Страница 81: ...ime If all the filters are active red all the messages will be displayed Time localization In addition to selecting the category you can also further limit the list of system messages by entering key data for the date and time Activate the checkbox next to Lower Time Click the field with the date display and select the desired date in the calendar which appears Select the desired time via the arro...

Страница 82: ...ated To export the correct list always click Apply before exporting Insert a floppy disk into the drive of your DMS DLS or insert a USB stick into an available USB port IMPORTANT If an exported archive file is already located on the floppy disk or the USB stick it is overwritten by the new archive file Select the storage medium you are using field A Then click Export Messages The end of the saving...

Страница 83: ...re the maximum size of the list can be defined using the Number of lines dialog You can open this by clicking on Number of lines Enter the maximum of messages you wish to save This setting will only take effect when the system updates the system messages in other words when it writes a new message to the protocol file Fig 13 6 ...

Страница 84: ...Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS 84 ...

Страница 85: ...nloading if the corresponding Extension has been carried out see the Installation and Configuration manual Service chapter Downloading a program Select the desired program in the Download Item box Select the program that you want to save in the Target box Floppy and USB stick can be selected Click OK NOTE The individual programs will not be described in more detail here For further information ple...

Страница 86: ...86 Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS ...

Страница 87: ...t browser as a user interface instead 15 1 Making the connection First access your system using your Internet browser You may have to open a data communications connection with TCP IP protocol Enter your address http xxx xxx xxx xxx x stands here for the IP address of the recording system to be accessed On the browser login page you can choose between Picture research DMS WebAccess and Picture vie...

Страница 88: ...Netscape Communicator from Version 3 x and up Abrowser plug in is required for viewing the pictures via the browser This can be downloaded directly via the recorder and installed 15 2 1 Installing plug in Click Install DMS Wavelet Plugin to install the plugin and execute the corresponding file Once the installation procedure starts the following window shows the browser for which the plug in is sa...

Страница 89: ...tions You are requested to login at the recorder in the following Enter your password and click Trans fer The valid passwords are the passwords stored in the DMS Please refer to the assignment of access rights for the Guest User Superuser and Administrator If your password was accepted the operator panel for further options and picture playback will appear Fig 15 5 Fig 15 6 Fig 15 4 ...

Страница 90: ... transfer as well The greater the compression the lower the quality of the picture and the higher the speed of transfer You can adjust the quality of the picture display using the small buttons digits 0 4 Clicking the 0 button will give you the lowest level of compression best picture quality while the 4 button will give you the highest compression Fig 15 9 Camera selection window Linear regulator...

Страница 91: ... levels The level of scaling selected will affect the amount of computation involved in decompression and can therefore be used to help reduce the load on your computer You must remember however that this also affects picture quality Camera filter The pictures of the defined cameras are found on track A B or C see Camera Configurations The pictures will therefore switch between cameras during play...

Страница 92: ...wser 15 3 Picture evaluation DMS WebAccess The DMS WebAccess research system is installed on DMS recorders as from Version 5 2 0 Only a standard browser is required in order to access the tracks of the recorder refer to the compatibility list No further plugins or additional software have to be installed 15 3 1 Compatibility DMS WebAccess has been tested successfully with the following browser ope...

Страница 93: ...he interface is displayed in German otherwise in English 4 Please note that WebAccess must have been activated at the recorder 15 3 2 Starting WebAccess Open the browser and enter the IP address of the recorder into the address line A In order to obtain access via DMS WebAccess click the login entry at DMSWebAccess B Enter your recorder password and confirm your entry by clicking OK 15 3 3 Evaluat...

Страница 94: ...sible thanks to the simple setting of band width and picture compression In addition to the simple track reading and picture playback numerous search options allow you to carry out very specific research In the process the picture data are displayed for each current picture and the 4 previous and subsequent event pictures are displayed in a preview strip The displayed research results can subseque...

Страница 95: ... found here If you click the button with the camera symbol A the list of active cameras is updated Activations Click the Activations button The Activations dialog is solely an information dialog on the outfitting of the system and no extensions can be made here Functions which are not activated with a check are either not integrated in your system or are not enabled Versions The Versions tab provi...

Страница 96: ...ation The CPU Information tab provides detailed information on the used CPU Signal information The Signal Information tab provides a simple possibility of checking the signal level not signal quality at the individual video inputs An optimal signal conforming to standards has an amplitude of 1Vpp 1000 mV Signal amplitudes that are too high or too low are displayed in yellow or red If you click the...

Страница 97: ...it can only be switched back on after shutdown by service or setup personnel Click the Shut Down button in the dialog selection Switching off and on again After switching the system off you must wait approx 10 seconds before you can switch it back on If you switch the system back on immediately it will not start up as the bridging voltage of the power supply has not yet discharged Restarting syste...

Страница 98: ...Dallmeier electronic GmbH Co KG Digital HD Recorders DMS DLS 98 ...

Страница 99: ...ilure due to overheating IMPORTANT Change the filter mat regularly at the latest when it is gray The frequency of filter changes is dependent upon the installation site and the degree of soiling associated with it In normal office rooms checking every three months is generally sufficient while a monthly check would be recommended for rooms with large amounts of dust storage etc Filter change proce...

Страница 100: ... DMS DLS 18 2 Cleaning the unit If the housing of your system is soiled use a dry cleaning cloth to clean it IMPORTANT Do not use cleansing agents or detergents Some cleansing agents and detergents contain solvents that can damage the surface of your system ...

Страница 101: ...pprox 2 minutes and switch recorder back on It takes a certain amount of time until all the hard disks are searched The larger the hard disk capacity the longer the search No pictures were recorded during the specified time Check whether any recordings were made with picture comparison with the sensitivity too low or whether the setting in the Areas dialog is wrong Check the existing video signal ...

Страница 102: ...oud fan noises If a password is lost please contact the installer or the support personnel at Dallmeier electronic A fan may have failed Notify the service personnel NOTE If technical problems occur whose cause you cannot eliminate yourself please contact your respective dealer sales partner If a fan fails the second fan runs continuously at the highest level ...

Страница 103: ...he following EC Directives Electromagnetic compatibility 89 336 EWG Low voltage 73 23 EWG The following specifications were applied Emmissions Limit class B in acc with EN 55022 1998 EN 61000 3 2 EN 61000 3 3 FCC Part 15 Subpart B Immunity Limit class B in acc with EN 55024 1998 EN 61000 4 2 IEC 61000 4 3 EN 61000 4 4 EN 61000 4 5 ENV 50141 DIN EN 60950 VDE 0805 1997 11 A11 1998 08 IEC 950 1991 A1...

Отзывы: