Rev. 1.0.2 | © 2018 Dallmeier | www.dallmeier.com 

1  Validity

This document applies to the following device:

• 

DF5400HD-DN/IR

For reasons of simplification, the term “device” or “camera” is used in the 

following.

Figures in this document may differ from the actual product.

2  Documents

The product documentation for the device contains several documents 

which are included in the scope of delivery in a printed form and/or on 

a digital medium. Additional information, if available, is provided exclu

-

sively on the website www.dallmeier.com.

Read the complete product documentation for the device carefully and 

thoroughly before using the device.

Always observe and follow the contained instructions, notes and warnings 

as well as the technical data in the currently valid product specification.

Keep all documents in legible condition and in a suitable location for 

future reference.

Regularly check the website www.dallmeier.com for the latest product 

documentation updates.

Содержание DF5400HD-DN/IR

Страница 1: ...006476 Rev 1 0 2 2018 12 14 DF5400HD DN IR Commissioning English...

Страница 2: ...ers Google and Google Chrome of Google Inc headquartered in Mountain View California USA JavaScript of Oracle Corporation and or its affiliates headquartered in Redwood Shores California USA Microsoft...

Страница 3: ...DF5400HD DN IR Rev 1 0 2 2018 Dallmeier www dallmeier com 3 1 1 1 1 1 1 4 4 4 1 1...

Страница 4: ......

Страница 5: ...ng 14 Warranty 14 Appropriate Use 14 Operation 15 Formation of Condensation Fogging of the Front Glass 16 Approvals Certifications 18 6 Requirements 19 Ambient Conditions 19 Power Supply 20 7 Maintena...

Страница 6: ...e of delivery in a printed form and or on a digital medium Additional information if available is provided exclu sively on the website www dallmeier com Read the complete product documentation for the...

Страница 7: ...urveillance systems installation contractors Other Applicable Documents Product Specification The product specification contains detailed technical data features and characteristics of the device The...

Страница 8: ...death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not avoid...

Страница 9: ...instructions one after the other in the sequence described Expressions in quotation marks usually refer to individual components of the device housing parts mounting elements connections interfaces et...

Страница 10: ...ppliances Periodic inspection on electrical appliances General requirements for electrical safety Regulations The use of video and audio security surveillance systems is in general strictly regulated...

Страница 11: ...ion If the device is brought from a cold to a warm environment resulting condensation may cause malfunctions and damage In this case wait until the device has reached room temperature up to 8 hours be...

Страница 12: ...Bodies in the Device If objects or liquids get into the device immediately disconnect it from the power supply pull out the power plug or disconnect the device from the PoE enabled PSE port Contact th...

Страница 13: ...in drill hole depth 40mm anchor length 30mm 1 Hexagon socket head cap screw fully threaded DIN 912 ISO 4762 M8 12 for hex key size 6mm 1 Hex key L wrench for hexagon socket screws key size 6mm 1 Hexal...

Страница 14: ...as an inte grated IR illumination The camera is equipped with an ambient light sensor that measures the intensity of visible light Depending on the lighting conditions the camera automatically switche...

Страница 15: ...tinuous operation in both indoor and outdoor areas The camera is operated via Power over Ethernet PoE Class 0 and is com patible with all IEEE 802 3af compliant Power Sourcing Equipment PSE Operation...

Страница 16: ...ay form on the outside of the housing as well as inside the device In this case wait until the temperature of the device will have slowly adapted to the ambient temperature prior to commis sioning Pre...

Страница 17: ...integrated IR lighting via the device s WebConfig user interface Set the IR power to the highest level until the glass is free of condensation due to the self heating generated by the IR LEDs This phe...

Страница 18: ...lass A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer ence when the equipment is operated in a commercial envir...

Страница 19: ...duct and may cause malfunctions or damages Do not install operate the device in places with a large amount of dust and dirt with steam or oil vapors e g kitchen with direct sunlight with strong heat e...

Страница 20: ...s well as damage to the device or malfunctions For the safety of persons protection against dangerous contact voltages and devices protection against lightning strikes and over voltages electrical sur...

Страница 21: ...the intensity of the electric field between the contacts rises sharply when un mating the jack plug connection The more un mating cycles are carried out under PoE load the higher the loss of contact m...

Страница 22: ...ary to clean the device observe the following notes NOTICE Damage to the surface of the device due to improper cleaning prac tices Clean the housing outside with a clean soft dry and antistatic cloth...

Страница 23: ...rding the maximum permissible carrying capacity of the supporting structure To mount the device only use screws and if necessary dowels that are suitable for the wall type and construction material su...

Страница 24: ...s are required for the installation Drilling template included in delivery Marking tool e g center punch or awl Drilling machine for expansion nylon plug S6 Torx 6 lobe drive screwdriver T25 Hex key L...

Страница 25: ...018 Dallmeier www dallmeier com 25 Remove the paper backing from the self adhesive gasket Adhere the gasket to the back of the outdoor wall mount bracket while ensuring that the gasket is aligned as i...

Страница 26: ...DF5400HD DN IR 26 Rev 1 0 2 2018 Dallmeier www dallmeier com Attach the provided IR lens hood to the sunshield as illustrated in Fig 3 and Fig 4 Fig 3...

Страница 27: ...the built in IR LEDs and thus to eliminate the so called halo effect and other undesirable effects that may lead to blurry foggy images Note that otherwise i e without the use of the IR lens hood some...

Страница 28: ...crew 5 40mm partly threaded pan head 6 lobe drive Torx T25 B 4 Plain washer VA DIN 9021 ISO 7093 inner diameter 5 3mm C 4 Expansion nylon plug S6 drill hole diameter 6mm min drill hole depth 40mm anch...

Страница 29: ...et as illustrated in Fig 2 Protect the device from direct influence of weather conditions rainfall direct sunlight etc Always use a protected installation site for outdoor installations e g under a pr...

Страница 30: ...ier com A Hexalobular L wrench Torx T8 included in delivery B Captive Torx screw T8 Fig 7 Open the flap on the bottom side of the wall mount bracket For this loosen the captive Torx screw B counter cl...

Страница 31: ...DF5400HD DN IR Rev 1 0 2 2018 Dallmeier www dallmeier com 31 Fig 8 C Ethernet cable of your local area network LAN C...

Страница 32: ...w dallmeier com A Pre assembled Cat 5e S UTP patch cable terminated with RJ45 8P8C modular plug male connector B Hexagon socket head cap screw fully threaded DIN 912 ISO 4762 M8 12 for hex key size 6m...

Страница 33: ...e assembled RJ45 patch cable A of the camera through the outdoor wall mount bracket Assemble the camera housing to the outdoor wall mount bracket as illustrated in Fig 9 and Fig 10 Tighten the provide...

Страница 34: ...re different ways to connect the camera to your LAN Use the provided Cat 5e RJ45 inline coupler STP Fig 11 and Fig 13 if the patch cable that is coming out of your wall is termi nated with an RJ45 8P8...

Страница 35: ...nsitions have to be wrapped with a self amalgamating tape in order to avoid damage to the RJ45 plugs jacks caused by moisture dust and dirt For an optimum protection against moisture dust and dirt we...

Страница 36: ...aptive Torx screw T8 C Flap sealing see Fig 15 and Fig 16 Fig 14 Close the flap on the bottom side of the wall mount bracket while ensuring that the flap sealing C is properly seated as illustrated in...

Страница 37: ...DF5400HD DN IR Rev 1 0 2 2018 Dallmeier www dallmeier com 37 Fig 15 Fig 16 C C...

Страница 38: ...og in to the user interface of the camera see section Login on page 44 Open the Lens control dialog of the camera Point the camera at your scene loosen the respective hexagon socket head cap screw wit...

Страница 39: ...2 2018 Dallmeier www dallmeier com 39 Fig 18 Detailed descriptions of the camera configuration such as zoom focus and IR illumination settings can be found in separate docu mentations that are availab...

Страница 40: ...Dallmeier www dallmeier com 9 Front View of Camera A Motor driven P Iris megapixel varifocal lens B Semi covert 850nm high power LED for homogeneous IR illumination C Ambient light sensor D Integrate...

Страница 41: ...com 41 10 Wire Color Code for Pre assembled Patch Cable Fig 20 Pre assembled Cat 5e S UTP patch cable terminated with RJ45 8P8C modular plug male connector Pin No Pair Color 1 2 Red 2 2 Orange 3 3 Bl...

Страница 42: ...port PoE injector is required to power the device System Requirements To configure the device the client PC must meet the following system requirements System Requirements Operating system OS Microsof...

Страница 43: ...your network administrator for more information and assistance Start the web browser Enter the IP address of the device into the address bar of the web browser Confirm the input The connection to the...

Страница 44: ...tentional misuse of the system Change the default login credentials of the administrator account as soon as possible Enter your login credentials Confirm with OK After the successful login the graphic...

Страница 45: ......

Страница 46: ...E TX 1000BASE T PoE IEEE 802 3af IR Illumination Type Semi covert 850nm high power LEDs IR intensity Adjustable Photocell Adjustable Day Night switching threshold level Range Up to approx 30m 98ft Bea...

Страница 47: ...oor and outdoor Operating temperature 40 C to 50 C 40 F to 122 F minimum start up temperature 30 C 22 F Relative humidity 0 90 RH non condensing Approvals Certifications Type CE FCC RCM UL DIN 50130 4...

Страница 48: ...DF5400HD DN IR 48 Rev 1 0 2 2018 Dallmeier www dallmeier com 13 Dimensions 71mm 2 81 99mm 3 89 364mm 14 31 231mm 9 08 88 mm 3 48 226 mm 8 90 138 mm 5 42 236mm 9 28 Fig 21...