DDF4920HDV-DN-IM Commissioning

 

Run the required cables through a PG16 cable gland and screw the PG16 

cable gland in the appropriate thread on the bottom side of the housing.

PG16 cable gland

Содержание DDF4920HDV-DN-IM

Страница 1: ...004688 2 0 2 2016 06 07 IM DDF4920HDV DN Commissioning English...

Страница 2: ...ks or registered trademarks of the following owners Adobe and Flash of Adobe Systems Incorporated headquartered in San Jos California USA AMD and AMD Athlon of Advanced Micro Devices Inc headquartered...

Страница 3: ...entions 5 4 Safety Instructions 7 5 General Notes 10 Scope of Delivery 10 Transportation and Packaging 10 Warranty 11 Approvals Certifications 11 Appropriate Use 11 6 Requirements 12 General 12 Operat...

Страница 4: ...ifications and features of the device The target audience is trained system integrators Commissioning The document Commissioning this document contains detailed descriptions on installation connection...

Страница 5: ...NGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious i...

Страница 6: ...uctions are indicated by arrows Carry out instructions one after the other in the sequence described Expressions in bold italics generally indicate a control element on the device switches or labels o...

Страница 7: ...appliances must be followed Regulations The use of video and audio surveillance systems is in general strictly regu lated Inform yourself about the currently valid laws and regulations regarding data...

Страница 8: ...ce has reached room tempera ture before commissioning Earthing Equipotential Bonding For the safety of persons protection against dangerous contact voltages and devices protection against over voltage...

Страница 9: ...from the power supply pull out the power plug Contact the sales partner responsible for your area Burnt Smell If you notice burnt smell or a formation of smoke coming from the device im mediately dis...

Страница 10: ...ry of destination The functional range of the device depends on the ordered equipment or device variant and may differ from this document s content Certain functions and features may require the purch...

Страница 11: ...tes Appropriate Use The DDF4920HDV DN IM in ceiling mount variant is a 5 megapixel HD network camera built into a vandal resistant IK10 dome enclosure It is exclusively designed for indoor installatio...

Страница 12: ...with improper ambient temperatures near sources with strong radiation e g radio transmitters magnetic fields with corrosive surroundings e g gases salt water with insufficient air ventilation e g clo...

Страница 13: ...gnal transformer balun for galvanic ground isolation between the signal source camera and the RG 59 cable If the device or the cables connected to the device are located near sources with strong radia...

Страница 14: ...ve the following notes NOTICE Damage to the surface of the device Clean the housing outside with a soft dry and antistatic cloth Do not use detergents Clean the plastic bubble with water and some dish...

Страница 15: ...quate carrying capacity of the supporting structure and the suspended ceiling or ceiling panel Use screws suitable for the ceiling wall material Use the correct type of anchor for your ceiling wall ty...

Страница 16: ...e not to use both power sources simultaneously In order to comply with UL s requirements always use a UL certified Limited Power Source LPS Class 2 power supply unit when operating the device with a s...

Страница 17: ...www dallmeier com 17 Commissioning DDF4920HDV DN IM Torx screwdriver T20 H...

Страница 18: ...18 www dallmeier com DDF4920HDV DN IM Commissioning Loosen the three tamper resistant torx screws Torx TR 20 of the cover ring with a torx screwdriver T20 H 3 Tamper resistant torx screw Torx TR 20...

Страница 19: ...www dallmeier com 19 Commissioning DDF4920HDV DN IM Remove the cover ring bubble...

Страница 20: ...20 www dallmeier com DDF4920HDV DN IM Commissioning Screw the M6 eye bolt onto the bottom side of the housing M6 eye bolt Ceiling clamp 2...

Страница 21: ...www dallmeier com 21 Commissioning DDF4920HDV DN IM Cut a circular hole 143mm into the suspended ceiling or ceiling panel Screw a ceiling hook into the supporting structure 143mm Ceiling hook...

Страница 22: ...22 www dallmeier com DDF4920HDV DN IM Commissioning Insert the housing into the circular cut out Basic position of ceiling clamp...

Страница 23: ...www dallmeier com 23 Commissioning DDF4920HDV DN IM Attach a safety wire to the M6 eye bolt use a carabiner and the ceiling hook Carabiner Safety wire...

Страница 24: ...24 www dallmeier com DDF4920HDV DN IM Commissioning M4 locking screw ceiling clamp Phillips screwdriver...

Страница 25: ...www dallmeier com 25 Commissioning DDF4920HDV DN IM Tighten the M4 locking screw of both ceiling clamps with a Phillips screw driver until the housing is securely fixed Locked ceiling clamp 2...

Страница 26: ...w dallmeier com DDF4920HDV DN IM Commissioning Run the required cables through a PG16 cable gland and screw the PG16 cable gland in the appropriate thread on the bottom side of the housing PG16 cable...

Страница 27: ...www dallmeier com 27 Commissioning DDF4920HDV DN IM...

Страница 28: ...28 www dallmeier com DDF4920HDV DN IM Commissioning Connect the required cables to the connectors of the camera module...

Страница 29: ...tion and detailed descriptions of the possible LAN LED states read the documentation on camera configuration Analog video output BNC CVBS DC auto iris interface LAN LED Audio OUT Microphone IN 3 5mm p...

Страница 30: ...30 www dallmeier com DDF4920HDV DN IM Commissioning SD SDHC card Min 1GB recommended Max 32GB supported...

Страница 31: ...www dallmeier com 31 Commissioning DDF4920HDV DN IM Rotation 180 Tilt 90 Pan 90 Knurled locking screw Rotation 2...

Страница 32: ...32 www dallmeier com DDF4920HDV DN IM Commissioning Ambient light sensor attached to adjustable foam ring Locking screw focal length...

Страница 33: ...Back Focus Control function After the manual focus setting on the lens a convenient and precise fine ad justment of the focus can be made over the network in the WebConfig user interface of the camer...

Страница 34: ...4 www dallmeier com DDF4920HDV DN IM Commissioning Attach the cover ring to the housing while ensuring that the ambient light sensor is not covered by the black inner dome cover Black inner dome cover...

Страница 35: ...www dallmeier com 35 Commissioning DDF4920HDV DN IM Tighten the three tamper resistant torx screws Torx TR 20 of the cover ring with a torx screwdriver T20 H...

Страница 36: ...p Signal Not used Ring Not used Signal Sleeve Ground Ground NOTICE For a clean interference free audio signal transmis sion the Audio IN OUT Y Cable Connector FGA 30 is required optionally available A...

Страница 37: ...eier com 37 Commissioning DDF4920HDV DN IM 12V DC Power IN Weidm ller male connector SL 3 50 02 90G DC auto iris interface Pin No Function DC auto iris 1 Control 2 Control 3 Drive 4 Drive 12V DC 12V D...

Страница 38: ...t crossover cable Minimum System Requirements Operating system OS Microsoft Windows XP Windows Vista Windows 7 each with latest service pack Processor CPU 3GHz Intel Pentium 4 AMD Athlon 64 3400 or fa...

Страница 39: ...llmeier Live Video ActiveX are not required for the configuration without live video display or live audio output the latest Dallmeier Live Video ActiveX can be directly downloaded from the device or...

Страница 40: ...168 2 28 Ensure that the PC web browser can establish a connection to the device via Ethernet Start the web browser Enter the IP address of the device into the address bar of the web browser Confirm t...

Страница 41: ...Risk of misuse by unauthorized users Change the factory default admin password as soon as possible Click CONFIG in the user interface of the live mode The login dialogue is displayed Enter the Userna...

Страница 42: ...length and the image section Audio OUT Microphone IN 1 3 5mm phone jack mono signal for stereo plug Mic IN max 63mV RMS input resistance 10kOhm internal gain 20dB Ethernet 1 RJ45 10BASE T 100BASE TX...

Страница 43: ...joules Dimensions Approx 170 H 135mm 6 7 H 5 3 Weight Approx 1200g 2 6lb Operating temperature 20 C to 40 C 4 F to 104 F Indoor Relative humidity 0 90 RH non condensing Approvals certifications CE FCC...

Страница 44: ...Dallmeier electronic GmbH Co KG Cranachweg 1 93051 Regensburg Germany Phone 49 0 941 87 00 0 Fax 49 0 941 87 00 180 www dallmeier com info dallmeier com...

Отзывы: