Dallas STX 165 Скачать руководство пользователя страница 3

After the software versions are displayed, the STX 165 display will revert to the normal operating mode.  The upper left
portion of the display will show the current tansmitter Mode. The upper right portion of the display will show the last code
that was selected prior to shut down, the Pressure Altitude (PALT) is displayed in the lower left and Elapsed Flight Time
(EFT) in the lower right of the display.  The built-in encoder requires a warm up time and the PALT value will show dashes
until the proper internal temperature is reached.

The user can set the mode to come on in the ALT mode at start up or at a predetermined altitude differential after takeoff.
The same is true for the EFT display.  See User Set Up for a discussion of these features.

3

Code Selection

To select a new squawk code you will use the Data/Select knob and pushbutton:

Press the Enter Pushbutton  the first digit in the squawk code will blink.
Rotate the smaller Data knob until the value of the codes first digit is displayed.
Rotate the larger Select knob clockwise to the stop and then release.  The second digit of the squawk code will be
blinking indicating that it can be changed.
Continue repeating the above steps until you have selected the desired s=code and then Press the Enter Pushbutton.
The new squawk code has been selected and is now being reported to ATC.

Note: The select knob is a spring load alternate action knob it can be turned
both clockwise and counter clockwise and will then return to center.

Mode Selection

To select the Mode of Operation you will use the Mode Control knob.

Rotate the Mode Control knob to select one of three transmitter Modes.

SBY

Standby.  The STX 165 is on but not responding to ATC interrogations

ON

The STX 165 is on and replying in Mode A (No Altitude Reporting)

ALT

The STX 165 is on and replying in Mode C (Altitude Reporting)

Содержание STX 165

Страница 1: ...wer pushbutton is also used to start the counters This is explained in the counter section SBY The STX 165 is in standby mode and will not respond to radar interrogations ON The STX is on and respondi...

Страница 2: ...exitthismode Thisfunctionisusefulinhighsunlightconditions particularlywithbubble canopies When power is first applied to the STX 165 the SANDIA aerospace logo will be displayed along with the unit ver...

Страница 3: ...ress the Enter Pushbutton the first digit in the squawk code will blink Rotate the smaller Data knob until the value of the codes first digit is displayed Rotate the larger Select knob clockwise to th...

Страница 4: ...sdependingontheUser Set Up selection IcingAlert IfanoptionalSANDIAaerospaceSTP78OATprobeisinstalledwiththeSTX165 itwilldisplay an IcingAlert in the upper right hand corner of the display when the temp...

Страница 5: ...own CNT DOWN allows the pilot to enter a specific time and then be alerted when that time has expired This timer is especially usefull for timed approached When activated the down time will count down...

Страница 6: ...Press the Enter pushbutton Note that if the Enter Pushbutton is not pressed within ten second the STX 165 will exit the set up mode Note The STX 165 must be in SBY mode to enter the User Set Up Functi...

Страница 7: ...mended If OFF is selected the pilot will be required to select the ON or ALT Mode TheSTX165startswiththeEFTdisplayedinthelowerrighthandcornerofthedisplay Theuser can set the EFTto begin counting at tu...

Страница 8: ...th 1200 as the VFR squawk code In some instance a different code is desirable for the VFR squawk To change the VFR squawk code 1 Rotate the Data knob to select the DEFAULTVFR page 2 PresstheEnterknob...

Отзывы: