INSTALLER’S INSTRUCTIONS   

 

 

                      

 

RELEASE 7.03 

 
 

 
 
 
 

Index 

 

DATA TAG 

 

ACCESSORIES LIST 

 

INSTALLER’S GUIDELINES 

 

INSTALLATION 

 

INITIAL SET UP 

 

HEATING 

 

GROUP DOSES PROGRAMMING 

 

MACHINE OPERATION 

 

MACHINE ADJUSTMENTS 

 

TEST 

 

ALARM ADMINISTRATION 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
    
 
 
 
 
 
 
 
 
 
 

 
 
 
 

l. 

13,5   

 

0.15 MPa 

INSTALLER’S MANUAL 

                                   

DATA TAG 

DALLA CORTE  

 S.r.l 

Via Broglio, 24 
20158 Milano Italy

 

Serial n° 

 

 

ANNO 2007 

MOD. 20.03 EVOLUTION 
 400 V 3N ~     

Hz 50 – 60 

 230 V 3 ~  
 230 ~  
WATT. 

 

IPX2 

Maximum water pressure 0.6 Mpa   

ATTENTION 

End user must set up electrical, water and drain systems in advance, to ensure a correct installation. 
Installer  can  not  modify  systems  set  up  in  advance  by  the  end  user  (see  chapter  “End  User  Set  Up 
Procedures” in the Use and Maintenance Manual enclosed with each unit.)  

 

ATTENTION 

The manufacturer reserves himself the right to modify the present manual without the obligation to up to 
date the previous editions. 

 

Содержание 20.03 EVOLUTION

Страница 1: ...l n ANNO 2007 MOD 20 03 EVOLUTION 400 V 3N Hz 50 60 230 V 3 230 WATT IPX2 Maximum water pressure 0 6 Mpa ATTENTION End user must set up electrical water and drain systems in advance to ensure a correc...

Страница 2: ...data tag applied to the unit Should the power cord be replaced for any reason use only a type with specs recommended by the manufacturer Machine can be operated safely only if properly grounded Machin...

Страница 3: ...such connector are distanced at least 3 mm from each other The operation described here above can be performed in two ways Connection to electrical circuit via suitable connector ATTENZIONE Perform in...

Страница 4: ...le hoses SYSTEM WITH WATER SOFTENER Softener is recommended in locations where water has over 10 French degrees of total hardness since it will prevent buildup of calcium deposits inside the machine T...

Страница 5: ...g espresso Buttons P2 and P5 are programmed the same way by using the double filter basket instead of the single By programming the doses on group nr 1 the same parameters are automatically copied on...

Страница 6: ...lect desired item on the menu chosen item will blink and push OK to confirm selection SET MENU Pushing OK while SET is blinking on the main menu will give access to the boiler and group heads temperat...

Страница 7: ...E T T I N G S D O S E S From the main menu push or until SETTINGS blinks and press OK to access the settings submenu G R O U P N x O N 2 This parameter sets the electronic board to match the number of...

Страница 8: ...his parameter sets the erogation time range allowed within which the erogation itself is considered correct referring to the lay out time already setted Default is 5 Range is between 5 to 20 Push or t...

Страница 9: ...water dose blinks push or to increase or decrease the value defualt is 6 0 Press OK to confirm Keep pressing the OK button until the display exits the DOSES menu and displays T E M P E R A T U R E S S...

Страница 10: ...0 0 Push to scroll down the submenu and display number of doses dispensed by group 1 T O T A L G R 1 0 0 0 0 0 0 Pushing will display R E S E T C O U N T E R S Y E S N O Pushing will display Select Y...

Страница 11: ...o scroll down the submenu until the display shows C H E C K G R I N D I N G 1 0 0 Push to scroll down the submenu C O U N T E R G R I N D I N G T E M P E R A T U R E S Push or to select TEMPERATURE an...

Страница 12: ...probes T P R O B E B O I L E R 1 2 1 0 C By pressing you see the probes n 1 2 3 and 4 one after the other T P R O B E G R 1 9 4 8 C Note The temperatures of the probes shown on the screen will range...

Страница 13: ...pressing OK again you go back to the OFF status By pressing you go to TRIAC 2 TRIAC 3 TRIAC 4 if they have been installed By pressing you go to RELAY STEAM solenoid valve of the MCS Milk Control Syst...

Страница 14: ...ne lockup LED s 7 and 8 turn on and machine emits a continuous beep To cancel the alarm turn the main switch of the machine off and back on This alarm is triggered when the electronic board senses the...

Страница 15: ...g button being used blinks To stop dispensing press button P3 of group 3 To cancel the alarm turn the main switch of the machine off and back on This alarm is triggered when the electronic board canno...

Страница 16: ...16 INSTALLER S INSTRUCTIONS RELEASE 7 03 WIRING DIAGRAM...

Страница 17: ...17 INSTALLER S INSTRUCTIONS RELEASE 7 03...

Страница 18: ...4 solenoid valve Ev the Hot water solenoid valve Rs gr1 Group 1 heating element Rs gr2 Group 2 heating element Rs gr3 Group 3 heating element Rs gr4 Group 4 heating element Ts1 Group 1 safety thermost...

Страница 19: ...19 INSTALLER S INSTRUCTIONS RELEASE 7 03 12 1 2 3 4 5 11 13 6 7 8 9 10 P1 Led1 P2 Led2 Led3 P3 Led6 P6 P5 Led4 P4 Led10 Led9 P7 Led8 Led7 Led5 GR 1 GR 2...

Страница 20: ...2 Adjustable foot 13 Hot water dispensing buttons P1 Dose button One short coffee P2 Dose button Two short coffees P3 Free dose and or Stop button P4 Dose button One long coffee P5 Dose button Two lon...

Отзывы: