9
INSTALLER’S INSTRUCTIONS
RELEASE 7.03
Without the GCS
system the display shows
C O F F E E - G R O U P - N . 1
s 1 - = - - 1 5 0 - - - - -
S1 (single short coffee ) blinks , push
or
to increase or decrease the value( default is 150)
Press
OK
to confirm
C O F F E E - G R O U P - N . 1
s 2 - = - - 3 0 0 - - - - -
S2 (double short coffee ) blinks, push
or
to increase or decrease the value(default is 300)
Press
OK
to confirm
C O F F E E - G R O U P - N . 1
s 3 - = - - 1 9 0 - - - - -
S3 (single long coffee ) blinks, push
or
to increase or decrease the value(default is 190)
Press
OK
to confirm
C O F F E E - G R O U P - N . 1
s 4 - = - - 3 6 0 - - - - -
S4 (double long coffee ) blinks, push
or
to increase or decrease the value(default is 360)
Press
OK
to confirm
C O F F E E - G R O U P - N . 2
s 1 - = - - 1 5 0 - - - - -
S1 (single short coffee ) blinks , push
or
to increase or decrease the value(default is 150)
Press
OK
to confirm. Repeat for each group until the display shows
- - T E A - - - G R O U P - - -
S 1 = - 3 . 0 - - S 2 = - 6 . 0
S1(single hot water dose)blinks, push
or
to increase or decrease the value( defualt is 3.0) Press
OK
to confirm. S2 ( double hot water dose ) blinks , push
or
to increase or decrease the value( defualt is
6.0) Press
OK
to confirm.
Keep pressing the OK button until the display exits the DOSES menu and displays
- - T E M P E R A T U R E S - -
S E T T I
N G S - - - D O S E S
With the GCS
system the display shows
- - G R . 1 - - - S e l . 1 - -
Q 1 = - 1 5 0 - - t 1 = - - 2 0
The display shows: Q1 dose from the selection 1 to the group 1 ( single short coffee ) using Grinder 1
You are not allowed to modify these parameters by using the serial palmer.
Press
OK
to confirm , the display shows
- - G R . 1 - - - S e l . 1 - -
Q 1 = - 1 5 0 - - t 2 = - - 2 0
The display shows : Q1 dose from selection 1 to the group 1 (single short coffee)using the Grinder 2
Press
OK
to confirm , the display shows
- - G R . 1 - - - S e l . 2 - -
Q 1 = - 3 0 0 - - t 2 = - - 2 0
The display shows : Q1 dose from selection 2 to the group 1 (double short coffee)using the Grinder 1
Press
OK
to confirm , the display shows
- - G R . 1 - - - S e l . 2 - -
Q 2 = - 3 0 0 - - t 2 = - - 2 0
The display shows : Q2 dose from selection 2 to the group 1 (double short coffee)using the Grinder 2
Going on this way you will visualize all doses parameters referred to the installed groups until the display
wil show TEA GROUP as already shown in the “WITHOUT GCS SUBMENU”
Sel 1 = single short coffee
Sel 2 = double short coffee
Содержание 20.03 EVOLUTION
Страница 16: ...16 INSTALLER S INSTRUCTIONS RELEASE 7 03 WIRING DIAGRAM...
Страница 17: ...17 INSTALLER S INSTRUCTIONS RELEASE 7 03...