Dali T9 Скачать руководство пользователя страница 10

10 

 [1] power switch

 

Used for turning on and off, standby and wake-up of the thermal imager. Press this 

switch for more than three seconds to turn on/off the thermal imager; short press to enter 

standby/wake up (any other key can also wake up). 

! Note

: It is recommended to wait at least ten seconds after turning off the camera and 

turning it on again to ensure the safety. 

[2] Mode key

   

Used to switch and zero the image mode. Short press to switch the image mode, 

there  are  4  image  modes  to  choose  from  infrared,  visible  light,  picture-in-picture  and 

dual-band fusion image; long press for 3 seconds to manually adjust the zero. 

[3] Back button

 

 

In  the  menu/edit  mode,  short  press  to  cancel  the  current  menu  operation  or 

return to the previous menu. 

 

In the active image mode, short press to auto focus. 

 [4] Storage key 

 

Used to freeze or save the image. Press this key once to freeze the image, press this 

key again to save the image, and press the return key to return to the active mode. Long 

press for 3 seconds to record, then short press to stop recording and save the video. 

[5] Five direction keys 

Including up, down, left, right and middle keys. It has different functions in different 

operation modes. 

 

In the menu mode (press the middle button to activate the menu and enter the 

menu mode), the up, down, left, and right buttons are used for the same level of 

menu operations, and the middle button enters the lower level menu or confirms 

the selection. 

 

In the active image mode, press the up and down buttons for digital zoom, and 

the left and right buttons for electric focus. 

[6] Trigger button  

Содержание T9

Страница 1: ...T9 T10 Thermal Imaging Camera User manual Copyright 2019 DALI TECHNOLOGY...

Страница 2: ...be directly aimed at a strong radiation source such as the sun direct or reflected laser beam etc otherwise it will Permanent damage to the thermal imager Caution The original packaging box must be u...

Страница 3: ...7 1 2 Optional configuration 8 2 Introduction 9 2 1 Button function 9 2 2 Interface 11 3 Operation 12 3 1 Battery installation and replacement 12 3 1 1 Battery loading and unloading 12 3 1 2 Battery r...

Страница 4: ...ack 25 4 8 Setting 26 4 8 1 Temperature measurement parameter setting 27 4 8 2 Temperature measurement function setting 28 4 8 3 Image setting 31 4 8 4 Storage setting 33 4 8 5 Connection setting 33 4...

Страница 5: ...easurement 1 arbitrary line temperature measurement 11 color codes can be selected Infrared and visible light image fusion Isothermal function Temperature measurement setting Fusion of high and low te...

Страница 6: ...rtcuts Power saving mode multi language Time date setting reset Upgrade options Optional wide angle lens 0 5x medium focus lens 2x or long focus lens 3x It can extend the temperature measurement at hi...

Страница 7: ...etection of the temperature of the slab produced from the furnace etc Fire protection forest fire prevention and potential fire source search spontaneous combustion prevention test of special material...

Страница 8: ...r USB data cable HDMI video cable 1 2 Optional configuration 0 5x wide angle lens 2x medium focal lens 3x telephoto lens Portable backpack Non national standard European standard British standard Aust...

Страница 9: ...9 2 Introduction 2 1 Button function 1 7 2 4 3 5 6 8...

Страница 10: ...ent menu operation or return to the previous menu In the active image mode short press to auto focus 4 Storage key Used to freeze or save the image Press this key once to freeze the image press this k...

Страница 11: ...en rotates the focusing ring clockwise to adjust the focus toward the far focus direction rotates the focusing ring counterclockwise to adjust the focus toward the near focus direction 2 2 Interface 1...

Страница 12: ...haped elastic area on both sides of the battery cover as shown by the red arrow and pull it outward to remove the battery When inserting the battery the battery is designed with a foolproof structure...

Страница 13: ...g storage in order to avoid possible over discharge during storage and affect the battery capacity the battery should be fully charged and stored And charge it at regular intervals The time interval i...

Страница 14: ...used batteries in accordance with local government regulations 3 3 Lens loading and unloading Align the red dot of the lens with the red dot in the instrument insert it carefully and rotate it clockwi...

Страница 15: ...ding temperature measurement objects see 4 2 Temperature Measurement Mode If you want to perform detailed temperature measurement of the thermal image displayed on the current screen you can store the...

Страница 16: ...erature measurement line press and hold the spot on the line you can drag the temperature measurement line as a whole press and hold any point at both ends of the line you can drag one end of the temp...

Страница 17: ...temperature measurement object as the reference object please refer to 4 8 2 Temperature measurement function setting Note The thermal imager can only set one reference temperature measurement target...

Страница 18: ...u interface and press the return button to exit the menu Icon interface When the secondary menu is an icon interface press the left and right buttons to switch icons press the middle button to confirm...

Страница 19: ...value of the temperature measurement object 2 Battery status Display the current battery power status 3 Storage mark indicates that the current image is being saved 4 Recording mark indicates that it...

Страница 20: ...easurement object 13 Compass logo indicates the current direction Note There are different functions in different modes and all the signs in the interface may not be displayed in various modes 4 1 2 D...

Страница 21: ...ture measurement objects including temperature measurement points temperature measurement areas temperature measurement lines etc Press the middle button or tap the touch screen to pop up the main men...

Страница 22: ...e a single temperature measurement object you can directly click the touch screen to select the temperature measurement object and then click the delete icon at the bottom of the screen to delete it 4...

Страница 23: ...lide your finger on the touch screen to adjust the upper and lower temperature values of the color code separately or at the same time Click the selected temperature value again to cancel the selectio...

Страница 24: ...This function is used to save the video The storage format of the video is MP4 screen recording or DLV only applicable to infrared images Continuing the operation from the previous section when the p...

Страница 25: ...Click the playback icon on the touch screen or use the left and right keys to select and then press the middle key to pop up the picture library interface as shown in the figure below Click the corre...

Страница 26: ...tch files by pressing the up down left and right buttons and press the middle button to open the playback Activate the icon to edit the file click the check box on the file and click the icon to delet...

Страница 27: ...ting After entering the setting menu interface use the buttons or touch screen to operate the menus at all levels which have been described in 3 4 7 menu operation instructions and will not be repeate...

Страница 28: ...nsmittance Spread ratio select process according to surface material and then select the corresponding material from the predefined material list you can also select custom value and then scroll up an...

Страница 29: ...e temperature measurement target can choose a temperature in point line or area and only one reference temperature measurement target can be set the reference temperature value can be selected by the...

Страница 30: ...ions can be set Alarm color setting When the target temperature exceeds the set alarm temperature the area exceeding the alarm temperature will be displayed in the set alarm color The system provides...

Страница 31: ...line temperature measurement and regional temperature measurement of the temperature measurement object including the highest temperature the lowest temperature the average temperature and the maximum...

Страница 32: ...the icon on the right side of Distance Setting Switch to turn it on or off When it is turned on the fusion distance will be adjusted according to the laser ranging result when it is turned off it sta...

Страница 33: ...ideo settings video format MP4 dlv can be selected dlv is only used for infrared images TF card format You can choose to confirm to format the TF card or choose to cancel to return Storage directory s...

Страница 34: ...lable devices and select available devices to connect after connecting you can disconnect the current operation 4 8 6 System setting In the system setting menu there are options such as language setti...

Страница 35: ...stem Information You can view information such as model number device number software version number MAC address etc Factory mode setting It is used inside the factory and requires a password to enter...

Страница 36: ...re independent 3 movable areas the highest temperature the lowest temperature capture average temperature measurement line temperature measurement isothermal analysis temperature difference measuremen...

Страница 37: ...tooth module Audio output input Bluetooth headset GPS Yes Electronic compass Yes Set up Date time temperature unit K language LCD backlight IP address 11 Environmental parameter Operating temperature...

Страница 38: ...ambient temperature is too low The rechargeable battery is not fully charged Recharge the rechargeable battery The rechargeable battery is completely exhausted and cannot be recharged Replace with a...

Страница 39: ...ass Polished plate 20 0 94 Paint White 100 0 92 Natural black 100 0 97 Carbon Smoky 25 0 95 Candle smoke 20 0 95 Graphite rough surface 20 0 98 Paint 16 colors average 100 0 94 Paper white 20 0 93 San...

Страница 40: ...ting parameter table Parameter Value Temperature alarm Turn off Alarm temperature 50 0 C Alarm color None Isothermal color Turn off Upper isothermal limit 51 C Lower isothermal limit 49 C Table 4 Syst...

Отзывы: