background image

3

  With subwoofer cable accessible, bring the SUB S-100 to 

the vicinity of the aperture and connect the cable to the 
subwoofer terminals as illustrated in Diagram 7.

 

Depending on cable routing in the wall, the SUB S-100 
subwoofer can be installed with the connection terminals 
either at the top or the bottom.

4

  Lift the SUB S-100 subwoofer into the aperture, being careful 

not to trap the cable, and hold it in place. Use a cross-head 
screwdriver or drill bit to tighten the eight dogleg clamp 
screws located in the subwoofer front panel. It is good 
practice to tighten opposite screws in turn.

DIAGRAM 7:
IN-WALL SUBWOOFER CONNECTIONS

NOTE

If the amplifier and audio system are connected and working, 
it is good practice at this stage to check the integrity and 
audio routing of the system by playing some audio and 
checking that the subwoofer is operating correctly before it 
is installed and secured in the wall.

Place subwoofer in wall.

3

Connect cables from the 

amplifier to the subwoofer.

4

13

Содержание PHANTOM IW SUB S-100

Страница 1: ...DALI PHANTOM IW SUB S 100 INSTALLATION MANUAL...

Страница 2: ...ng and Installation 6 4 1 Positioning 7 4 2 In wall Installation 9 4 2 1 Cables 9 4 2 2 Wall Aperture 10 4 2 3 In wall Installation 11 4 2 4 On wall Installation 15 4 2 5 Unmounted Installation 17 5 0...

Страница 3: ...ion on amplifier to subwoofer routing and connections can be found in the CI AMP 2500 DSP Installation Manual available for download from dali speakers com NOTE The matching DALI PHANTOM CI AMP 2500 D...

Страница 4: ...S 100 subwoofer If necessary consult an appropriately qualified structural engineer for advice When installing a SUB S 100 in a plasterboard dry wall we recommend that two layers of plasterboard are u...

Страница 5: ...d in Diagram 1 are present 1 x DALI PHANTOM IW SUB S 100 1 x Grille magnetic 1 x Cut out template 4 x Rubber pads DIAGRAM 1 CONTENTS We recommend that packaging materials are retained in case the SUB...

Страница 6: ...s SUB S 100 subwoofers can be installed singularly or in multiples Although the SUB S 100 is primarily intended for In wall installation it can also be installed on wall using an appropriate DALI On w...

Страница 7: ...led it is best located near the floor of the listening room in or on the wall that also carries the front left and right channel speakers The closer the subwoofer is to the corner of the room the more...

Страница 8: ...me location guidelines as for In wall installation should generally be followed The use of SUB S 100 subwoofers unmounted lying on their back however does potentially enable concealed installation on...

Страница 9: ...ty is retained The red positive subwoofer terminal must be connected to the positive amplifier terminal The black negative subwoofer terminal must be connected to the negative amplifier terminal To in...

Страница 10: ...mps make it possible to install SUB S 100 in a wall up to 70 mm 2 75 in thick The supplied cut out template can be used initially to visualise where a SUB S 100 is to be installed As part of this exer...

Страница 11: ...ws The SUB S 100 subwoofer incorporates eight dogleg clamps for In wall installation The clamps secure the subwoofer firmly to the rear of the wall surface on which it is mounted The dogleg clamps ext...

Страница 12: ...e wall can be found and secured to the inside wall surface to prevent any undue cable tension when it is connected to the subwoofer terminals If a subwoofer cable has not been previously installed the...

Страница 13: ...hold it in place Use a cross head screwdriver or drill bit to tighten the eight dogleg clamp screws located in the subwoofer front panel It is good practice to tighten opposite screws in turn DIAGRAM...

Страница 14: ...a torque limiting type and have its torque set to minimum Installing the subwoofer in the wall aperture and tightening the clamps is shown in Diagram 8 6 With the SUB S 100 subwoofer secured in the wa...

Страница 15: ...Frame can be secured to a flat wall and then the SUB S 100 subwoofer installed within it Diagram 9 illustrates subwoofer installation in an PHANTOM OW frame S 80 Once the PHANTOM OW frame S 80 is secu...

Страница 16: ...d screws appropriate for the type of wall 1 Landscape Portrait Pass the cable from the amplifier unit through the channels of the frame Cable diameter Max 10 mm 2 DIAGRAM 9 ON WALL INSTALLATION 8 x Co...

Страница 17: ...bly should be laid on its back when used unmounted Four adhesive felt pads are supplied with the SUB S 100 and should be applied to the back of the On wall Frame to provide cushioning on hard floors W...

Страница 18: ...amplifier unit through the channels of the frame Place the 4 rubber feet on the rear side of the DALI PHANTOM OW frame S 80 2 Connect cables from the amplifier to the subwoofer 3 Use a cross head scr...

Страница 19: ...or electronic materials The presence of these materials may if not disposed of properly have potential adverse effects on the environment and human health Presence of this label on the product means i...

Страница 20: ...Outer dimensions incl grille H x W x D 657 x 412 x 107 mm 25 87 x 16 22 x 4 22 inches Outer dimensions excl grille H x W x D 647 x 402 x 106 mm 25 5 x 15 9 x 4 21 inches Cut out dimensions H x W 615 x...

Отзывы: