         It’s better to replace batteries now.

      

3.2  Battery safety and usage

           

Batteries should be stored in an ambient temperature of -4

  (–20

) to 

67.9

 (+20

). Lithium batteries will self-discharge during storage, so they should be 

fully charged before storage.  Self-discharge may affect long term battery performance. 

Furthermore, it is recommended that the battery should be charged in a set time, as 

below;

Ambient temperature of:
    

   ●

 -4 ℉ (–20℃ ) to 67.9 ℉ (+20℃ ), once  every 6 months

   

     ●

 67.9 ℉ (+20℃ ) to 113 ℉ (+45℃ ), once every 3 months

      

● 

113 ℉ (+45℃ ) to 149 ℉ (+60℃ ), once every month

      

Battery should have greater than 50% charge prior to recharge.

       →

The ambient temperature for charging should be 32

 (0

) to 104

 

(+40

). If under 32

 (0

), the battery capacity will be diminished; if over 104

 

(+40

), the battery may overheat, resulting in permanent damage.

         

WARNING:

         ●

 Never disassemble, incinerate or puncture battery

         ●

 Never short circuit the battery

         ●

 Keep battery dry

         ●

 Keep out of reach of children

         ●

 Always dispose of battery in accordance with local, state and federal regulations

Содержание LT3

Страница 1: ...LT3 LT7 Thermal Image Camera User Manual ZHEJIANG DALI TECHNOLOGY CO LTD...

Страница 2: ...ing carton should be kept for use for future transportation Do not drop shake or impact the thermal imager excessively in use or during transportation CAUTION Store the unit in its original case in a...

Страница 3: ...g battery 13 3 2 Battery safety and usage 14 3 3 Quick access 15 3 3 1 Capture an image 15 3 3 2 Temperature measurement 15 3 3 3 Freeze and save image 16 3 3 4 Viewing stored Images 16 3 3 5 Export s...

Страница 4: ...4 4 7 Factory Default 27 4 5 File 28 4 5 1 Open 28 4 5 2 Save 29 4 5 3 Save Setting 31 4 5 4 Auto Save 32 4 5 5 Delete 32 4 5 6 Format 33 5 Technical specifications 34 Troubleshooting 36 Appendix A 37...

Страница 5: ...uto or manual level and span control or K measurement scale 11 user selectable color palettes 9 user selectable languages Hot temperature spot measurement Cold temperature spot measurement 4 removable...

Страница 6: ...and residential energy audits Moisture detection Determine root cause of moisture and mildew Evaluation Evaluate the resolution to ensure the area completely dry Others Iron and steel industry Inspec...

Страница 7: ...er manual Infrared report and analysis software system CD Lithium battery charger Lens cap TF card TF card reader USB cable 1 2 Optional accessories External 0 5x wide angle lens External 2x telescopi...

Страница 8: ...7 LT3 LT7 Thermal Image Camera User Manual DALI 2 Camera overview 2 1 Function keys...

Страница 9: ...key will pop up the attribute box In this box the user can select to adjust either position or size of the area After selection the arrows will then adjust the attribute Color Palette Pressing the lef...

Страница 10: ...n key to activate X2 digital zoom The screen will display X2 in the upper left corner Press Up or Down key to return to the original image In Spot Measurement editing mode activated immediately after...

Страница 11: ...eleasing trigger again removes the spot Area Pulling and releasing trigger adds an area Pulling and releasing trigger again removes the area Save the same with S key pressing to initiate a Save cycle...

Страница 12: ...o computer for data transmission only support USB2 0 2 TF Card slot Accepting standard size TF card such as supplied 2GB capacity card for device upgrade or image storage 3 Video port It is a video ou...

Страница 13: ...ttery Installation and Replacement 3 1 1 Inserting or removing battery Battery compartment is located inside the handle Turn the cover counter clockwise to remove Remove battery for replacement Insert...

Страница 14: ...eplacement battery Use of incorrect battery may result in physical or electrical damage to the instrument due to incorrect voltage or physical size difference 3 1 2 Replacing battery When battery has...

Страница 15: ...arged in a set time as below Ambient temperature of 4 20 to 67 9 20 once every 6 months 67 9 20 to 113 45 once every 3 months 113 45 to 149 60 once every month Battery should have greater than 50 char...

Страница 16: ...ss CONFIRM and scroll left or right to select the proper measurement parameter Aim the cursor indicator onto the target object on the screen The temperature will be displayed in the upper right corner...

Страница 17: ...ed parameter will be adjusted by the directional arrow keys When Set Ref is set as Yes the displayed values of other measurements will be their delta from this measurement 3 3 3 Freeze and save image...

Страница 18: ...es of each saved image it will display No Image if there is no CCD image for that saved image If the trigger is configured to IR CCD mode by Setup Sys Setup Trigger when in image view the trigger can...

Страница 19: ...te Palette bar User can choose different palettes 8 Maximum temperature Indicates maximum value of the palette 9 Battery status Indicates the current battery status 10 11 Result Indicates the temperat...

Страница 20: ...l menu is available accessed by the right arrow key 4 1 3 Dialog box 1 Dialog box name Displays the dialog box name e g Measuring Setup 2 Item title A dialog box may contain several items such as Temp...

Страница 21: ...in the image Designated by SH and H Add Cold Spot adds a moving cursor that automatically displays the coldest spot in the image Designated by SL and L Add Spot adds up to 2 fixed cursors user adjusta...

Страница 22: ...ollowed by a Pressing the key followed by the Confirm key will switch to the displayed mode Press A key to select palette or adjust it manually In Auto mode the camera automatically determines the low...

Страница 23: ...ce temperature Press Up and Down keys to choose different items Left and Right keys to modify the item contents Temp Range Select Temp Range according to target temperature LT7 low Temp Range 20 180 o...

Страница 24: ...te the main menu Select Setup Adjustment and press Confirm key to pop up the Adjustment dialog box User may set emissivity temperature correct and ambient temperature Press Up and Down keys to choose...

Страница 25: ...n Max or Average will have to meet or exceed the set temperature in order to trigger the alarm Temp Alarm Off disables alarm function On enables alarm function and allows setting of Set Alarm Temp and...

Страница 26: ...nd Down keys to choose menu items Left and Right keys to modify the item contents NOTE If the imager is not used for a long period the system clock may need reset due to the internal battery being dep...

Страница 27: ...Area Temp Save key and IR CCD Laser Allows user to Turn on and turn off the laser sight Spot Temp Adds or deletes Spot Measurement Area Temp Adds or deletes Area Measurement Save key Initiates the sav...

Страница 28: ...s the Model number Serial number Version number and Date of Manufacture 4 4 7 Factory Default It is used for resetting factory defaults Press Menu key to activate the main menu Select Setup Default an...

Страница 29: ...ete images stored on the TF card 4 5 File 4 5 1 Open Press Menu key to activate the main menu Select File Open press Confirm key to open the saved images Press Left and Right keys to change the images...

Страница 30: ...stored 4 5 2 Save It is used for saving the image performs the same functionality as the Save key Press Menu key to activate the main menu Select File Save press Confirm key to save the current image...

Страница 31: ...art Speak clearly into the microphone on the control panel Record function allows up to 60 seconds of recording time and may be stopped at any time by pressing the Confirm key If the TF card is not in...

Страница 32: ...not occur and may result in lower accuracy images when saved Always save thermal images with thermal camera active when Link Save is ON NOTE When Imager is in Link Save Mode a prompt Please do now mo...

Страница 33: ...Auto Save dialog box Press Left and Right keys to set the values Press the Confirm key to accept and recording timer will start saving images at the selected interval 4 5 5 Delete Used for deleting th...

Страница 34: ...ivate the main menu Select File Format and press Confirm key to pop up the below dialog box Press Confirm key to do format press C key to cancel the format CAUTION Before formatting make sure all file...

Страница 35: ...or Image control Color palette 11 palettes changeable Image adjustment Auto manual gain and brightness Setup functions Date time temperature unit language Emissivity correction Variable from 0 01 to 1...

Страница 36: ...torage 90 non condensing Encapsulation IP54 Drop test 2m Physical characteristics Weight 980g Dimension 105 245 230mm Interface SD card slot Micro SD card slot External DC input YES Video output YES U...

Страница 37: ...tection is enabled Wait for 5 seconds and reboot The camera powers off automatically Battery is out of power Change battery AutoOffTime option is enabled Set as None Battery depletion is too fast Envi...

Страница 38: ...0 64 Non Oxidized 100 0 21 Wrought iron Quarry faced 25 0 94 Polished 38 0 28 Nickel Oxidized 200 0 37 Stainless steel Oxidized 60 0 85 Steel Oxidized 200 0 79 Common brick Surface 20 0 93 Concrete Su...

Страница 39: ...mp 30 Table 2 Measurement temperature correction table Parameter Value Emissivity 0 96 TCorrect 0 TAmbient Temp Off Table 3 Analysis setting table Parameter Value Temp Alarm Off Alarming Temp 50 0 Ala...

Страница 40: ...ZHEJIANG DALI TECHNOLOGY CO LTD Add 639 Binkang Road Hangzhou P R China 310053 Tel 86 571 86695603 Fax 86 571 86695600 http www dali tech com E mail sales dali tech com...