Adeo Control SGDD-C4-4 Driver (Adeo_Control_SGDD-C4-4_Gateway.c4z)
System Design
USE FADE
The need to introduce the direct 'set' command, without the use of a ramp, was
necessary because some devices do not support the reception of continuous
commands, typical of fade/ramping variations. Specifically, if such devices receive
unsupported commands, they have uncontrolled behaviour and provide incorrect
feedback to the physical gateway.
This property affects the communication protocol used between the Control4 driver-
gateway and the SGDD-C4-3:
•
yes: all commands sent from the driver to the physical gateway are fade/ramping
commands with a minimum time of 100 ms.
•
no: the driver sends 'set' commands (without fade/ramping) to the physical gateway
Debug Mode
Enable or disable debugging in Lua
Polling Interval
"
OFF
,
10
or
60
" sets the time in seconds for polling, i.e. to receive information from the
gateway. The recommended value is always OFF, in order not to overload the
communication channel.