Adeo Group s.r.l.
Via della Zarga n. 50 - 38015 LAVIS (TN)
Tel: +39 0461 248211 - Fax: +39 0461 245038
Mail: [email protected]
Adeo Control SGDD-C4-4
Manual
Rev. 1.6
Adeo Control is a brand of Adeo Group s.r.l.
16
/
36
SETTINGS
15.
Network
The gateway uses the Ethernet port via IPv4 protocol.
The default IP address is: 192.168.1.4
The same address must be entered in
Composer Pro
in the
Connections/Network
section
After changing the settings, click on the top right button
'APPLY'
otherwise the changes will be
lost.
16.
Login settings
After logging in as
ADMIN
, you can change your username and password by clicking on
Login
Settings
.
After changing the settings, click on the top right button "
APPLY
" otherwise the changes will be
lost.
17.
sACN
The gateway implements the sACN protocol and can be used as a gateway by the main lighting
software and controllers:
•
sACN
→
DMX
•
sACN
→
DALI
The port used is there UDP 5568.
After changing the settings click on the top right button "
APPLY
" otherwise the changes will be
lost.