The fan should be assembled by a qualified person that has been trained appropriately.

-

 

During assembly, the fan and its auxiliary controls should be disconnected from power supply. The working tools 
should be insulated.

-

 

Do not carry the device by grasping the installation box or the cables. Grasp the device by the housing at all times. 
While doing so, do not press the fan's grille.

-

 

Wear protective gloves during assembly to prevent injury due to sharp edges on the fan and working tools.

EN

EN

The fan is composed of the housing, impeller, and electric motor.

The fan body is made of aluminium. The impeller is made of galvanised steel with blades bent forwards.

For a dimensioned figure, see PIC1.

Model

Dimensions (mm)

Net 

maximum 

weight 

(kg)

A

B

C

D

E

F

G

SKT ALU 120E

100 

70

55

80

140

180

210

2.45

SKT ALU 140E

100

90

75

80

140

200

230

2.57

SKT ALU 140ER

100

90

75

80

140

200

230

2.98

SKT ALU 160E

115

105

90

95

150

230

265

3.63

SKT ALU 160ER

115

105

90

95

150

230

265

3.82

Parameter

SKT ALU 120E

SKT ALU 140E SKT ALU 140ER SKT ALU 160E SKT ALU 160ER

Static pressure (Pa)

230

410

450

490

560

Power input (W)

90

130

165

173

185

Speed (rpm)

2,450

2,410

2,390

2,320

2,285

Rated current (A)

0.40

0.53

0

.

60

0.80

0.85

Acoustic noise (dB/3m)

60

67

69

72

74

Frequency (Hz)

50

Voltage (V)

220–240

3

Air flow rate (m /h)

395

550

660

730

850

Connection to the electric power network

Before  connection  to  the  electric  power  network  make  sure  that  its  parameters  (frequency,  power  and  current) 
correspond to the requirements of the device.

1.

 

Disconnect the circuit of the electric power network on which you are going to work.

2.

 

Unscrew the cover of the installation box.

3.

 

Read the wiring diagram (PIC2) carefully.

4.

 

Connect the wires according to the diagram and make sure that the device is earthed. 

5.

 

Re-place the installation box housing and screw it firmly. 

Assembly

After unpacking the device, check it for damage during transport. If any part is missing or damaged, inform the carrier 
or seller immediately.

The length of the duct connected to the fan must be at least 1 m and the duct must be attached firmly. A duct shorter 
than 1 m must be covered with the attached grille in accordance with EN ISO 13857:2008. 

After assembly

-

 

Check that the device is wired and earthed correctly, and that all safety regulations have been complied with.

-

 

Check that the installation box has been properly assembled and that no water enters it.

-

 

Check that the fan's impeller rotates in the right direction.

-

 

Check that the arrow indicating the direction of air flow on the fan housing corresponds to the direction in which the 
impeller rotates. 

-

 

Check that air movement is not obstructed by any obstacle.

-

 

There should be no vibration and internal friction and no impact noises should occur during the rotation of the 
impeller and the intake of air.  When starting the device for the first time, check it after it has run for 1 hour. The fan 
should not make any unusual sounds or vibrate excessively.

-

 

If you encounter problems that are not addressed by this user manual, please contact a specialist.

Technical specifications

Before assembly

Содержание SKT ALU Series

Страница 1: ...SKT ALU GEBRAUCHSANWEISUNG HASZN LATI TMUTAT N VOD K POU IT INSTRUKCJA OBS UGI N VOD NA POU ITIE INSTRUC IUNILE USER MANUAL...

Страница 2: ...en s rga z ld ty zielony galben verde EN DE CZ SK HU PL RO BG j SKT ALU k Accessories Zubeh r p slu enstv pr slu enstvo tartoz kok akcesoria accesorii l Duct Rohrleitung potrub potrubie cs ruroci g co...

Страница 3: ...ended for use by persons including children with reduced physical sensory or mental abilities or lack of experience and knowledge if they are not supervised or the person responsible for their safety...

Страница 4: ...90 75 80 140 200 230 2 57 SKT ALU 140ER 100 90 75 80 140 200 230 2 98 SKT ALU 160E 115 105 90 95 150 230 265 3 63 SKT ALU 160ER 115 105 90 95 150 230 265 3 82 Parameter SKT ALU 120E SKT ALU 140E SKT...

Страница 5: ...After unpacking the device check it for damage during transport If any part is missing or damaged inform the carrier or seller immediately The length of the duct connected to the fan must be at least...

Страница 6: ...he duct and to power supply CAUTION The motor may not come into contact with water or cleaning agents during cleaning Do not use ammable or explosive cleaning agents CAUTION Inspect the fan regularly...

Страница 7: ...ersonen einschlie lich Kinder mit verminderten k rperlichen sinnlichen oder mentalen F higkeiten oder mit unzureichender Erfahrung und Kenntnis bestimmt oder sofern ihnen die f r ihre Sicherheit veran...

Страница 8: ...T ALU 140E 100 90 75 80 140 200 230 2 57 SKT ALU 140ER 100 90 75 80 140 200 230 2 98 SKT ALU 160E 115 105 90 95 150 230 265 3 63 SKT ALU 160ER 115 105 90 95 150 230 265 3 82 Parameter SKT ALU 120E SKT...

Страница 9: ...ntuelle Besch digung w hrend des Transports Sofern ein Teil fehlt oder besch digt ist benachrichtigen Sie sofort den Spediteur oder den H ndler Die L nge des an den Ventilator angeschlossenen Rohres m...

Страница 10: ...f der Motor nicht mit Wasser oder Reinigungsmitteln in Ber hrung kommen Verwenden Sie keine brennbaren oder explosiven Reinigungsmittel ACHTUNG Kontrollieren Sie den Ventilator regelm ig und tauschen...

Страница 11: ...en mi fyzick mi smyslov mi i ment ln mi schopnostmi nebo nedostatkem zku enost a znalost pokud nejsou pod dohledem nebo jim osoba odpov dn za jejich bezpe nost nepodala instrukce k pou v n P klad Dal...

Страница 12: ...0 90 75 80 140 200 230 2 57 SKT ALU 140ER 100 90 75 80 140 200 230 2 98 SKT ALU 160E 115 105 90 95 150 230 265 3 63 SKT ALU 160ER 115 105 90 95 150 230 265 3 82 Parametr SKT ALU 120E SKT ALU 140E SKT...

Страница 13: ...o rozbalen p stroje zkontrolujte zdali nedo lo b hem p epravy k po kozen Pokud jak koliv st chyb nebo je po kozen informujte obratem dopravce nebo prodejce D lka potrub p ipojen ho k ventil toru mus b...

Страница 14: ...u s vodou nebo ist c mi prost edky Nepou vejte ho lav ani v bu n ist c prost edky POZOR Ventil tor pravideln kontrolujte a bez prodlen nahrazujte poru en nebo opot ebovan kabely matice a dal sou stky...

Страница 15: ...fyzick mi zmyslov mi alebo ment lnymi schopnos ami alebo nedostatkom sk senost a znalost ak nie s pod doh adom alebo ak im osoba zodpovedn za ich bezpe nos neposkytla in trukcie na pou vanie Pr klad D...

Страница 16: ...E 100 90 75 80 140 200 230 2 57 SKT ALU 140ER 100 90 75 80 140 200 230 2 98 SKT ALU 160E 115 105 90 95 150 230 265 3 63 SKT ALU 160ER 115 105 90 95 150 230 265 3 82 Parameter SKT ALU 120E SKT ALU 140E...

Страница 17: ...ont Po rozbalen pr stroja skontrolujte i sa po as prepravy nepo kodil Ak ak ko vek as ch ba alebo je po koden informujte obratom dopravcu alebo predajcu D ka potrubia pripojen ho k ventil toru mus by...

Страница 18: ...taktu s vodou alebo istiacimi prostriedkami Nepou vajte hor av ani v bu n istiace prostriedky POZOR Ventil tor pravidelne kontrolujte a ihne nahr dzajte poru en alebo opotrebovan k ble matice a al ie...

Страница 19: ...ikai rz kszervi vagy szellemi k pess gekkel vagy el gtelen tapasztalattal s tud ssal rendelkez szem lyek bele rtve a gyerekeket is amennyiben nem llnak fel gyelet alatt vagy ha a biztons guk rt felel...

Страница 20: ...0 230 2 57 SKT ALU 140ER 100 90 75 80 140 200 230 2 98 SKT ALU 160E 115 105 90 95 150 230 265 3 63 SKT ALU 160ER 115 105 90 95 150 230 265 3 82 Param ter SKT ALU 120E SKT ALU 140E SKT ALU 140ER SKT AL...

Страница 21: ...gol sa ut n ellen rizze hogy nem s r lt e meg a sz ll t s sor n Ha b rmely alkatr sz hi nyzik vagy megs r lt k rj k azonnal rtes tse a sz ll t t vagy a keresked t Aventil torhoz csatlakoztatott cs hos...

Страница 22: ...v zzel vagy tiszt t szerekkel Ne haszn ljon gy l kony vagy robban svesz lyes tiszt t szereket FIGYELEM Rendszeresen ellen rizze a ventil tort s halad ktalanul cser lje ki a t r tt vagy kopott k beleke...

Страница 23: ...awno ci zyczn zmys ow lub psychiczn lub nieposiadaj ce do wiadczenia i wiedzy je eli nie s pod nadzorem lub osoba odpowiedzialna za ich bezpiecze stwo nie pouczy a ich o u ywaniu Przyk ad Dalap SKTALU...

Страница 24: ...00 90 75 80 140 200 230 2 57 SKT ALU 140ER 100 90 75 80 140 200 230 2 98 SKT ALU 160E 115 105 90 95 150 230 265 3 63 SKT ALU 160ER 115 105 90 95 150 230 265 3 82 Parametr SKT ALU 120E SKT ALU 140E SKT...

Страница 25: ...transportu Je eli jakiejkolwiek cz ci brakuje lub jest uszkodzona niezw ocznie informowa przewo nika lub sprzedawc D ugo ruroci gu pod czonego do wentylatora musi wynosi co najmniej 1 m a ruroci g mu...

Страница 26: ...ub rodkami czyszcz cymi Nie u ywa atwopalnych lub wybuchowych rodk w czyszcz cych UWAGA Regularnie kontrolowa wentylator i niezw ocznie wymienia uszkodzone lub zu yte kable nakr tki i inne cz ci Zasad...

Страница 27: ...opii cu dizabilit i zice senzoriale sau mintale Utilizatorii f r experien i care nu cunosc aparatul sau cei c rora nu li s au furnizat instruc iunile de utilizare trebuie s e supraveghea i de o persoa...

Страница 28: ...SKT ALU 140E 100 90 75 80 140 200 230 2 57 SKT ALU 140ER 100 90 75 80 140 200 230 2 98 SKT ALU 160E 115 105 90 95 150 230 265 3 63 SKT ALU 160ER 115 105 90 95 150 230 265 3 82 Parametru SKT ALU 120E...

Страница 29: ...pachetare asigura i v c aparatul nu a fost deteriorat n timpul transportului Dac lipse te vreo component sau este deteriorat informa i imediat transportatorul sau v nz torul Lungimea conductei conecta...

Страница 30: ...n contact cu apa sau cu agen i de cur are Nu utiliza i agen i de cur are in amabili sau explozivi ATEN IE Veri ca i ventilatorul n mod regulat i nlocui i f r nt rziere cablurile piuli ele i alte compo...

Страница 31: ...31 BG BG BG 220 240 V 50 Hz IP44 Dalap SKTALU 140 ER Dalap SKT ALU 0 C 40 C SKT ALU 120E 120 mm 2450 140E 140 mm 2410 140ER 140 mm 2390 160E 160 mm 2320 160ER 160 mm 2285...

Страница 32: ...75 80 140 200 230 2 98 SKT ALU 160E 115 105 90 95 150 230 265 3 63 SKT ALU 160ER 115 105 90 95 150 230 265 3 82 SKT ALU 120E SKT ALU 140E SKT ALU 140ER SKT ALU 160E SKT ALU 160ER Pa 230 410 450 490 56...

Страница 33: ...33 BG BG BG 1 2 3 2 4 5 1 m 1 m EN ISO 13857 2008...

Страница 34: ...34 Ventil tor nen po dn upevn n nebo je patn nainstalovan BG BG BG 6 40 C 80 C 80 2...

Страница 35: ...35...

Страница 36: ...Trieden odpad elektrick a elektronick zariadenia Szelekt v hullad k elektromos s elektronikus berendez sek Sortowany odpad urz dzenia elektryczne i elektroniczne Reciclarea de eurilor Echipamente elec...

Отзывы: