Please read this manual carefully and pay attention to all the requirements before use.
It is prohibited to install the fan into ducting systems that are used to conduct flue gases away.
The installation, connection and maintenance of the fan may only be done when the fan is disconnected from the
mains.
The timer and humidistat may only be set after the fan has been disconnected from the mains.
Both connection to and disconnection from the supply network should only be done by a specialist electrician.
This device is not intended for use by persons (including children) with reduced physical, sensory or mental abilities or
lack of experience and knowledge, if they are not supervised or the person responsible for their safety has not provided
them with the instructions for use.
The fan is designed for connection to single-phase alternating current 220–240 V with a frequency of 50 Hz.
The degree of protection is IP24. Operating temperature from +1 to +40 °C.
USES
The Dalap NOMIA household axial fan is intended for use in small and medium sized residential and non-residential
units.
The fans may be used for continuous ventilation.
SAFETY REQUIREMENTS
NOMIA (models without timer and humidistat)
Connection:
1)
Switch off the electric circuit that you are going to work on.
2)
Unscrew the screw on the front panel's side and remove the cover under which the terminal block with two
terminals is located.
3)
Run the supply cables (permanent phase and neutral) through the rubber bushing and connect them in the
terminal block. The positions of the cable connections do not matter in this case.
4)
After completing the installation, connect the electric circuit and test the function of the fan.
NOMIA Z (models with timer and light sensor)
Basic information about the connection:
1)
Switch off the electric circuit that you are going to work on.
2)
Unscrew the screw on the front panel's side and remove the cover under which the terminal block with three
terminals is located.
3)
The terminals are marked with letters T (interruptible phase), L (permanent phase) a N (neutral).
4)
Read the wiring diagram carefully (PIC 5a, PIC 5b, PIC 5c).
5)
Run the supply cables through the rubber bushing and connect them in the terminal block as seen in the wiring
diagram.
6)
Set the timer (Time).
7)
Set the I/II/III jumper and the A/B jumper depending on the mode selected (see below).
8)
After completing the installation, connect the electric circuit and switch on the fan.