Manual # 650444A
2. Remove the stock gauge assembly from the center gauge
bezel; the only items to be reused are the front bezel and
the gauge mounting hardware. Now is a good time to clean
or refinish the bezel.
3. Peel the paper off the two block-off lenses needed
(636234-A and 636234-B) and place them shiny side
down in the two rectangular openings. Use silicone to
hold them in place and avoid handling until the
silicone has cured.
636234-B
636234-A
4. With the block-off lenses in place, position the VHX center gauges over the back of the center
bezel and secure the system by using the four (4) stock mounting screws.
5. Attach the provided 60” CAT5 Cable and the 3-Pin Switch
Harness to the back of the VHX display. Carefully route the
other ends to the control box mounting location. Refer to
manual 650360 for switch wiring instructions before
reassembly of the center gauges to the dash using stock
hardware.