Dakota Digital SGI-5 E Скачать руководство пользователя страница 8

 

 

MAN# 650528 rev. B 

 

APPLICATION #6 (



 

Convert a 4000ppm signal from an OEM transmission speed sensor or ECM output to an 8000ppm 
signal for an aftermarket speedometer. 
 

The speed sensors have a two-pin connector on the transmission or transfer case.  One of the 

pins will be a ground and the other will be the signal.  The ground pin will go the GROUND terminal 
along with the ground wire.  The signal pin will go to the SIGNAL IN terminal.  It is best to twist the 
signal and ground wires from the sensor around each other.  This helps eliminate any electrical 
interference.  If nothing else is connected to the speed sensor it does not matter which pin is used as 
the ground.  If you are picking up a signal coming out of the ECM there will be only one wire to the 
SIGNAL IN.  Connect the POWER terminal to accessory power and the GROUND terminal to 
ground.  The CAL ratio should be set to 2.000 as a starting point.  Connect OUT1 to your aftermarket 
electric speedometer. 
 
 

APPLICATION #7 (



 

Convert a 8000ppm or 16000ppm signal from a cable drive speed sensor to a 128000ppm signal for 
an OEM speedometer or ECM. 
 

Either two wire or three wire sensors can be recalibrated with this unit.  Two wire sensors will 

typically have one wire as a ground and the other as the signal.  Three wire sensors will have an 
additional power wire.  You must first determine which wire is the signal.  The signal wire will be 
tapped into so the SGI-5 E can read it.  The sensor signal wire will go to the SIGNAL IN terminal.  
Connect the POWER terminal to a 12-volt accessory wire and connect the GROUND terminal to a 
good ground location.  If nothing else is connected to a two wire sensor, then connect one wire to the 
GROUND terminal also. The output connections will depend on your particular application.  

With an 

8000ppm signal the CAL ratio can start out at 1.00.  If starting with a 16000ppm signal the CAL 
ratio should be set to 0.500 as a starting point.

  Here are some typical examples: 

 
OUT3, 128000ppm AC: 

most common if OEM sensor connected to ECM direclty 

OUT4, 128000ppm oc: 

most common if an ECM was fed by another electronic module 

 SENSOR

 G

N

D

 GROU

N

D

 POW

E

R

 O

UT

 2

 O

UT

 1

 SEN

SO

PW

R

 SIG

NA

IN

 O

UT

 4

 O

UT

 3

SE

T

IN

C

SGI-5 E

 O

UT

 5

+

-

UNIVER

SAL SPEE

D

 I

N

T

E

R

F

A

C

E

da

k

o

tad

ig

it

a

l.c

o

m

12V Accessory Power

GROUND

Sensor ground (if needed)

Speed input signal

Sensor 5V power (if needed)

128000 ppm 'oc' output

128000 ppm 'AC' output

ppm values listed
below are only valid

after calibration is
complete

 

Содержание SGI-5 E

Страница 1: ...ter 5 Convert a 16000ppm signal from a VDO Hall Effect signal generator to an 8000ppm 4000ppm or 2000ppm to run a cruise control or fuel injection computer 6 Convert a 4000ppm signal from an OEM trans...

Страница 2: ...in low speed out OUT3 4 of OUT1 OUT5 of OUT1 1 Begin with the key off 2 Press and hold the SET switch while turning the key on The display will show the current version code 3 Release the SET switch T...

Страница 3: ...l is displayed then press and release the SET switch 5 The display will show the ones digit of the currently stored calibration value Press and release the INC switch to set this from 0 4 for your des...

Страница 4: ...or buffer side will go to the OUT1 terminal If the speedometer does not operate correctly after installation of the SGI 5 you may need to switch to OUT2 instead of OUT1 Connect the POWER terminal to...

Страница 5: ...WER terminal to a 12 volt accessory wire and connect the GROUND terminal to a good ground location You can determine how far the speedometer is off by having it checked with radar a GPS unit or follow...

Страница 6: ...ome typical examples OUT3 8000ppm AC most aftermarket speedometers and cruise controls OUT4 4000ppm oc most TPI computers and some OEM cruise controls OUT5 2000ppm oc most TBI computers and some OEM c...

Страница 7: ...2000ppm oc most TBI computers and some OEM cruise controls APPLICATION 5 Convert a 16000ppm signal from a Hall Effect signal generator to 8000ppm 4000ppm or 2000ppm to run a cruise control or fuel inj...

Страница 8: ...wire sensors can be recalibrated with this unit Two wire sensors will typically have one wire as a ground and the other as the signal Three wire sensors will have an additional power wire You must fir...

Страница 9: ...switch while turning the key on The display will show the current version code 3 Release the SET switch The display will show 4 Press and release the INC switch until is shown 5 Press and release the...

Страница 10: ...nical support line 605 332 6513 to request a Return Merchandise Authorization number Package the product in a good quality box along with plenty of packing material Ship the product by UPS or insured...