Dakota Digital PAC-2000 Скачать руководство пользователя страница 4

 

 

 

MAN# 650113D

 

Custom Calibration 

Note 1:   If your engine is warm you may need to disconnect the wire from your sender in order get to the lower  

points on the gauge. 

Note 2:  If the key is turned off in custom setup, the previous gauge setting will be used and the custom gauge will  

not be saved.

 

 

  CC1.  Select 

 in Step 9 above. Display will read 

 

CC2.  Turn the potentiometer on the lower right corner of the unit (marked CUSTOM ADJUSTMENT) with a 

small flat screw driver. While doing so, watch your temp gauge and line up the needle with the 

lowest

 

mark on the gauge. 

Custom gauge must be calibrated starting at cold temperatures and moving to 

hot temperatures.  

 

Note: Turning potentiometer clockwise increases temperature reading. 

 

CC3.  Once the gauge is set to a mark, press SW1 or SW2. A temperature reading will appear on the display. 

Scroll to the temp that matches the mark on the gauge using SW1 to increase and SW2 to decrease. 
Press both buttons to save the number. Display will again read 

 

CC4.  Repeat steps CC2 and CC3 with the next lowest mark on gauge until all the marks on your gauge have 

been set. (up to 6 but no less than 4 points). 

 

Press both SW1 and SW2 at 

  to stop setting points if 

there are less than 6 points on your gauge. If there are more than 6 points on your gauge, select points 
over the full range of the gauge (cold to hot). This will give a better match to your gauge.  

  

11. 

Unit will flash 

 to indicate set up is complete. The unit now has been set up. If the wiring and setup have 

been properly completed the unit should begin normal operation at this point.  

 

Resetting Factory presets

 

This procedure will return the device to the original factory presets and clear custom calibration settings.  

NOTE: Calibration data for the custom gauge setup will be lost when reset to factory presets. 

 

  1. Turn key off. 

 

  2. Press and hold SW1 and SW2 and turn key on.  

 

  3. Display will read 

 for reset 

 

  4. Display will flash 

 to indicate unit is reset. Factory reset values are listed at the  

      beginning of the setup portion of this manual. 
 

Checking set up (diagnostic mode) 

This unit comes with a feature to allow you to mimic normal operating temperatures using the  
adjustment pot. This can allow you to test the installation before ever starting the engine. Just  
follow these steps. 
 

 

  1. 

Turn the key on. 

 

  2. 

Press SW1 and SW2 at the same time and hold. A number representing the temperature will come up on the 
display. This number will blink once to indicate that the unit has entered diagnostic mode. SW1 and SW2 may 
now be released and the unit will remain in diagnostic mode until the key is turned off. 

 

  3. 

Adjust the potentiometer on the left side of the unit while watching the display and listening for the fan. The fan 
should start when the display reads hotter than the set on temp. It should again shut off when the display reads 
lower than the off temp.  

 

  4. 

You may also look at your water temperature gauge (if unit is using a gauge) and compare the temperature 
reading of the unit to the gauge. The temperatures should be within a few degrees. If not, the wrong gauge may 
be selected in the setup routine. Go through setup again by turning off the ignition, pressing and holding SW2 and 
turning ignition back on. If a selection cannot be found that closely matches your gauge you may have to custom 
calibrate to your gauge. (see step 10 in setup)  

 

Checking the current reading 

The current temperature reading can be displayed on the unit at anytime during normal operation, without going into the 
diagnostic mode. Simply press and hold SW1 while the key is on and the PAC-2000 is not in setup or diagnostic mode. 
The current temperature will be shown on the display until the SW1 is released. 
 
 

 

Содержание PAC-2000

Страница 1: ...CONNECTED NOT CONNECTED FAN2 12V NOT CONNECTED NOT CONNECTED LOW FAN1 FAN HIGH 12V Not used in sender only application 12 V with key ON A C clutch cycle switch Fused battery 12V Choose option below SENDER GAUGE single fan two separate fans dual speed fan REV D Fan High Fan High Fan Low Fan Low 12V NOT CONNECTED FAN NOT CONNECTED Fan Low Fan High 12v trigger ...

Страница 2: ...nteed to properly control the fan possibly leading to overheating and engine damage If a gauge is not used ONLY a Dakota Digital 300 F sender should be used Other senders may not give a correct reading to control unit Required components for installation The PAC 2000 is shipped with necessary components for use with a single fan on a gauged system These parts include 1 PAC 2000 module 1 RLY 1 rela...

Страница 3: ...o run for 45 seconds after key is turned off If fan was running at key off it will continue to run for 1 minute after key is turned off If fan was running at key off it will continue to run for 2 minutes after key is turned off If fan was running at key off it will continue to run for 3 minutes after key is turned off If fan was running at key off it will continue to run for 5 minutes after key is...

Страница 4: ...om gauge setup will be lost when reset to factory presets 1 Turn key off 2 Press and hold SW1 and SW2 and turn key on 3 Display will read for reset 4 Display will flash to indicate unit is reset Factory reset values are listed at the beginning of the setup portion of this manual Checking set up diagnostic mode This unit comes with a feature to allow you to mimic normal operating temperatures using...

Страница 5: ...ery Shorten fan delay time to prevent excessive battery drain Fan turns on late or not at all Unit has no power Broken shorted wire to sender Wrong gauge is selected gauge setup Wrong sender used for no gauge setup On temperature in setup is too high Fan not connected properly Alternator overcharging Analog gauge applications only With key on hold SW1 if the display doesn t show a temperature afte...

Страница 6: ...must include a copy of the dated sales receipt from your place of purchase Send no money We will bill you after repair Dakota Digital 24 Month Warranty DAKOTA DIGITAL warrants to the ORIGINAL PURCHASER of this product that should it under normal use and condition be proven defective in material or workmanship within 24 MONTHS FROM THE DATE OF PURCHASE such defect s will be repaired or replaced at ...

Отзывы: