Troubleshooting guide.

 

          Problem   

 

          Possible cause   

 

           Solution  

 

 

 

Gauge will not light up   

PWR terminal does not have 

Connect to a location that has power. 

 

 

 

 

  power. 

 

 

 

 

GND terminal is not getting 

Connect ground to a different location. 

 

 

 

 

  a good ground. 

 

 

 

 

Display harness is unplugged.  Seat connectors in tightly at both ends. 

 

 

 

 

Gauge is damaged. 

 

Return gauge for repair.  (see instructions) 

 

Gauge lights up, but  

 

Sensors are not connected. 

Check sensor connections at control unit and 

displays “---”.     

 

 

 

 

 

  sensor. 

 

 

 

 

Sensor is damaged. 

 

Call for replacement.  (contact factory) 

 

 

 

 

Sensor is out of range.   

Make sure pressures and temps are not   

 

 

 

 

 

 

 

 

  exceeding sensor limits. 

 

 

 

             Gauge is damaged. 

 

Return gauge for repair.  (contact factory) 

 

Gauge lights up, but  

 

Sensors are not connected. 

Check sensor connections at control unit and 

displays “EEE”.   

 

 

 

 

 

  sensor. 

 

 

 

 

Sensor is damaged. 

 

Call for replacement.  (contact factory) 

 

 

 

 

Sensor is out of range.   

Make sure pressures and temps are not   

 

 

 

 

 

 

 

 

  exceeding sensor limits. 

 

 

 

             Gauge is damaged. 

 

Return gauge for repair.  (contact factory) 

 

Gauge lights up, but does 

Loose connection on  

 

Reconnect wire going to PWR terminal. 

  not read correctly. 

 

  power wire. 

 

 

 

 

Poor sender connection. 

Make sure sender is connected to control unit. 

 

 

 

 

Poor ground connection. 

Move ground to different location 

 

 

 

 

Incorrect sender type.   

Make sure sender has been replaced with 

 

 

 

 

 

 

 

 

  the correct type  

 

 

Temperature unit is not set 

See “Setting temperature setup” in the   

 

               correctly (F or C) 

 

  manual. 

 

 

Voltage or wiring problem 

Check wiring harness for loose or damaged 

 

 

 

 

  in vehicle wiring harness. 

  wires. 

 

 

 

 

Calibration value is incorrect. 

Check setup and adjust. 

 

 

 

 

Sensor is not installed properly.  Check instructions and wiring.    

 

 

Gauge flashes constantly. 

Warning limits are not set 

Reset warning limits. 

 

 

 

 

  properly. 

External warning indicator 

Indicator not connected   

Check indicator wiring connections. 

  does not work.  

 

  properly. 

 

 

 

 

Indicator does not work.  

Repair or replace indicator. 

 

 

 

 

Gauge output has been   

Return gauge for repair.  (see instructions) 

 

 

 

 

  damaged. 

 

 

 

 

External relay could be    

Check relay or replace.   

 

 

 

 

  damaged. 

 

 

 

 

 

 

 

 

 

Gauge will not dim. 

 

DIM terminal is not connected 

Check wiring connections. 

 

 

 

 

  correctly. 

 

 

 

 

Gauge is damaged. 

 

Return gauge for repair.  (contact factory) 

 

Gauge remains dim at all 

DIM terminal is getting power 

Connect DIM terminal to location that only 

  times.   

 

 

  all of the time.   

 

  has power when the headlights are on. 

 

 

 

 

Battery is very low. 

 

Recharge or replace vehicle battery. 

 

 

 

 

Gauge is damaged. 

 

Return gauge for repair.  (contact factory) 

 

Gauge lights and displays 

 

 

 

(pressing and releasing the switch will allow the gauge to  

SETUP  

 

 

 

 

 

 

function but values displayed may be incorrect) 

ERROR  

 

 

Multiple errors in setup menu 

 

 

Go through setup menu 

ERROR1 

 

 

Temp unit error  

 

 

 

Reset Temp unit in setup menu 

ERROR2 

 

 

Warning point error Temp, EGT, or Boost 

Reset warning points in setup  

ERROR3 

 

 

Warning poring error Boost2  

 

 

Reset the BST2 Warn value 

ERROR4 

 

 

Atmospheric pressure zero point error 

 

Try the auto cal in BST CAL 

ERROR5 

 

 

Gauge calibration off  

 

 

 

Send gauge in  

ERROR6 

 

 

Display mode is corrupted___ 

 

 

Change UPDATE speed in Setup 

 

Содержание Odyssey ODYR-25-1

Страница 1: ...no tape or thread sealant should be used on the threads Make sure that the sender tip can get into the coolant flow If the sender cannot ground through its threads then a ground will have to be connec...

Страница 2: ...while turning the key on The menus are as follows SET MODE start of the setup menus indicates setup mode Main Menu Sub Menu Description BOOST BOST CAL auto calibrate the boost sensor to current condit...

Страница 3: ...to convert inHg to PSIA PSIA inHg 2 Press and release the switch to select the appropriate PSIA reading Press and hold the button until the gauge dims to save the new calibration value and continue w...

Страница 4: ...witch to continue with setup EGT WARNING SETUP The temp warning point can be set from 1150 1770 F 620 1770 C Press and hold the switch when HI WARN is displayed Once the display dims release the switc...

Страница 5: ...mperature readings Boost calibration routine to compensate for atmospheric pressure changes due to weather elevation High boost readings up to 85 psi Two warn outputs for an external warning light or...

Страница 6: ...Because of the wide temperature span the gauge may not be as accurate below 100 F 38 C The EGT gauge uses a thermocouple sensor to measure the temperature The thermocouple consists of a screw in exhau...

Страница 7: ...F or C manual Voltage or wiring problem Check wiring harness for loose or damaged in vehicle wiring harness wires Calibration value is incorrect Check setup and adjust Sensor is not installed properly...

Страница 8: ...telephone number where you can be reached during the day Any returns for warranty work must include a copy of the dated sales receipt from your place of purchase Send no money We will bill you after...

Отзывы: