Operation: 

The gauge needs only the RED and BLACK wires connected to light up.  When the 

BLUE wire has 12 volts, it will dim the display for night viewing.  The BIM-19 provides all of the 
sensor connections and attaches to the gauge with the supplied power/data cable.  

The 

senders must be Dakota Digital part SEN-03-9.

  Sending units from other manufacturers will 

cause incorrect readings.  SEN-03-9 

has 1/8” NPT threads.  If other thread sizes are needed, 

an adapter fitting should be used to change the thread size.  If a sender is giving an incorrect 
reading, the display will show “EE”.  If the sender is shorted to ground, the display will show “--”. 

The display will flash and the warning output will be set whenever one of the displayed 

pressures is out of the warning set limits. 

When the tank pressure sender is connected, pressing the switch on the front of the 

gauge will switch between displaying the bag pressures and the tank pressure. 

The default setup for the BIM-19-2 will work correctly with the ODYR-19-7 kit.  Additional 

specifics about the BIM-19-2 can be found in its separate manual. 

 

Air Ride setup options: 

 

 

4 bag   

 

3 bag   

 

Front/Rear 

 

Left/Right 

 

LR 

LEFT REAR   

REAR  

 

REAR  

 

LEFT 

RR 

RIGHT REAR 

not connected 

not connected 

RIGHT 

LF 

LEFT FRONT 

LEFT FRONT 

FRONT 

 

not connected  

RF 

RIGHT FRONT 

RIGHT FRONT 

not connected 

not connected 

TNK  - 

TANK (optional for all bag setups) 

 

Specs for each input are: 

Part #  

Range    

resolution 

low warning  high warning 

SEN-03-9 

0 - 300psi 

 

– 252  

48 

– 300 

 

Using external warning indicators: 

The WHITE wire provides a ground trigger whenever any of the senders are outside the 

set limits.  Low current indicators (less than 1/2 A) can be activated directly by connecting their 
power wire to 12 volts and connecting their ground wire to the WHITE wire. 

For higher current buzzers or lights, a relay will need to be used to switch the indicator 

on.  Dakota Digital’s RLY-1 30A relay may be used for this.  One of the coil wires should be 
connected to 12 volts and the other coil wire connected to the WHITE wire.  When the gauge is 
outside its limits, the relay will turn on.  The relay contact wires can be used to switch the higher 
current. 
 

Mounting: 

The gauge requires a round hole 2-

1/16” in diameter.  It should be inserted into the 

opening from the front and the U-clamp will be installed from the back.  Tighten the two nuts on 
the U-clamp so that the gauge is secure.  Gauge depth to the back of the case is 1-1/2

”.  Gauge 

depth including the mounting studs is 2-3

/8”. 

The BIM-19 can be mounted to wood, metal, or plastic using screws with the two mounting 
holes, double sided tape, or hook and loop fasteners. 