5
MAN#650446
Troubleshooting guide.
Problem
Possible cause
Solution
Gauge will not light up
PWR terminal does not have
Connect to a location that has power.
power.
GND terminal is not getting
Connect ground to a different location.
a good ground.
Gauge is damaged.
Return gauge for repair. (see instructions)
Gauge lights up, but displays
BIM-19-1 is not connected.
Connect a BIM-19 using the 3.5mm data cable.
“No Senders Found”
BIM-19-1 is not powered.
Check power connections on BIM-19.
Data cable is not plugged in
Check both ends of the data cable.
securely.
Gauge lights up, but displays
BIM-19-1 is not connected.
Connect a BIM-19 using the 3.5mm data cable.
“BIM-19 SIGNAL ERROR”
BIM-19-1 is not powered.
Check power connections on BIM-19.
Data cable is not plugged in
Check both ends of the data cable.
securely.
Gauge lights up, but
Sender is not connected
Connect wires from sender to BIM-19
displays “EE”.
to BIM-19.
terminals.
Wires are crossed or shorted.
Verify sender connection to BIM-19.
Wire between BIM-19 and
Test and replace wire.
sender is broken.
BIM-19 is damaged.
Return gauge for repair. (see instructions)
Sender is damaged.
Return for replacement. (see instructions)
Gauge lights up, but
Sender wire is shorted to
Check wire for damaged insulation, replace
displays “--”.
ground.
if necessary.
Wire between BIM-19 and
Test and replace wire.
sender is broken.
BIM-19 is damaged.
Return gauge for repair. (see instructions)
Sender is damaged.
Return for replacement. (see instructions)
Gauge lights up, but does
Loose connection on
Reconnect wire going to PWR terminal.
not read correctly.
power wire.
Poor sender ground.
Make sure gauge and BIM are getting a solid
ground.
Poor ground connection.
Move ground to different location
Incorrect sender type.
Make sure sender has been replaced with
the correct type (SEN-03-9).
Gauge flashes constantly.
Warning limits are not set
Reset warning limits.
properly.
Vehicle has improper air
Check air level and air pump.
pressure.
External warning indicator
Indicator not connected
Check indicator wiring connections.
does not work.
properly.
Indicator does not work.
Repair or replace indicator.
Gauge output has been
Return gauge for repair. (see instructions)
damaged.
Gauge will not dim.
DIM terminal is not connected
Check wiring connections.
correctly.
Gauge is damaged.
Return gauge for repair. (see instructions)
Gauge remains dim at all
DIM terminal is getting power
Connect DIM terminal to location that only
times.
all of the time.
has power when the headlights are on.
Battery is very low.
Recharge or replace vehicle battery.
Gauge is damaged.
Return gauge for repair. (see instructions)