background image

 

5

 

MAN#650446 

Troubleshooting guide. 
 

Problem 

 

 

Possible cause   

 

Solution 

 
Gauge will not light up   

PWR terminal does not have 

Connect to a location that has power. 

 

 

 

 

  power. 

 

 

 

 

GND terminal is not getting 

Connect ground to a different location. 

 

 

 

 

  a good ground. 

 

 

 

 

Gauge is damaged. 

 

Return gauge for repair.  (see instructions) 

Gauge lights up, but displays  

BIM-19-1 is not connected. 

Connect a BIM-19 using the 3.5mm data cable. 

“No Senders Found” 

 

BIM-19-1 is not powered. 

Check power connections on BIM-19. 

 

 

 

 

Data cable is not plugged in 

Check both ends of the data cable. 

 

 

 

 

  securely. 

Gauge lights up, but displays  

BIM-19-1 is not connected. 

Connect a BIM-19 using the 3.5mm data cable. 

“BIM-19 SIGNAL ERROR” 

BIM-19-1 is not powered. 

Check power connections on BIM-19. 

 

 

 

 

Data cable is not plugged in 

Check both ends of the data cable. 

 

 

 

 

  securely. 

Gauge lights up, but 

 

Sender is not connected  

Connect wires from sender to BIM-19 

  displays “EE”.   

 

  to BIM-19. 

 

 

  terminals. 

 

 

 

 

Wires are crossed or shorted. 

Verify sender connection to BIM-19. 

 

 

 

 

Wire between BIM-19 and 

Test and replace wire. 

 

 

 

 

  sender is broken. 

 

 

 

 

BIM-19 is damaged. 

 

Return gauge for repair.  (see instructions) 

 

 

 

 

Sender is damaged. 

 

Return for replacement.  (see instructions) 

Gauge lights up, but  

 

Sender wire is shorted to 

Check wire for damaged insulation, replace 

  displays “--”.   

 

  ground. 

 

 

  if necessary. 

 

 

 

 

Wire between BIM-19 and 

Test and replace wire. 

 

 

 

 

  sender is broken. 

 

 

 

 

BIM-19 is damaged. 

 

Return gauge for repair.  (see instructions) 

 

 

 

 

Sender is damaged. 

 

Return for replacement.  (see instructions) 

Gauge lights up, but does 

Loose connection on  

 

Reconnect wire going to PWR terminal. 

  not read correctly. 

 

  power wire. 

 

 

 

 

Poor sender ground. 

 

Make sure gauge and BIM are getting a solid 

 

 

 

 

 

 

 

 

  ground. 

 

 

 

 

Poor ground connection. 

Move ground to different location 

 

 

 

 

Incorrect sender type.   

Make sure sender has been replaced with 

 

 

 

 

 

 

 

 

  the correct type (SEN-03-9). 

Gauge flashes constantly. 

Warning limits are not set 

Reset warning limits. 

 

 

 

 

  properly. 

 

 

 

 

Vehicle has improper air  

Check air level and air pump. 

 

 

 

 

  pressure. 

External warning indicator 

Indicator not connected   

Check indicator wiring connections. 

  does not work.  

 

  properly. 

 

 

 

 

Indicator does not work.  

Repair or replace indicator. 

 

 

 

 

Gauge output has been   

Return gauge for repair.  (see instructions) 

 

 

 

 

  damaged. 

Gauge will not dim. 

 

DIM terminal is not connected 

Check wiring connections. 

 

 

 

 

  correctly. 

 

 

 

 

Gauge is damaged. 

 

Return gauge for repair.  (see instructions) 

Gauge remains dim at all 

DIM terminal is getting power 

Connect DIM terminal to location that only 

  times.   

 

 

  all of the time.   

 

  has power when the headlights are on. 

 

 

 

 

Battery is very low. 

 

Recharge or replace vehicle battery. 

 

 

 

 

Gauge is damaged. 

 

Return gauge for repair.  (see instructions) 

 
 

Отзывы: