8
MAN#650477:D
tach
Tachometer warning setup
•
Press and release the switch until “
tach
” is displayed, then press and hold the switch until the display blanks.
•
Release the switch. The display will
show “
hi
”, the current rpm warning (2200 – 8200), and “
warning
”.
•
Press and release the switch to change the value, press and hold the switch to select it.
oil temp
Engine oil temperature setup menu
•
Press and release the switch until “
oil temp
” is displayed, then press and hold the switch until the display blanks.
•
Release the switch. The display will show
“
ON
” or “
OFF
” depending on whether the reading is currently enabled.
•
Press and release the switch to change the selection, press and hold to save it.
•
If
ON
is selected, the next option is
“
SENDER
”, “
warning
”, “
test
”, or “
DONE
”.
•
Press and release the switch to change the selection, press and hold the switch to select it.
SENDER
Temperature sender and F/C selection
•
Press and release the switch until “
sender
” is displayed, then press and hold the switch until the display blanks.
•
Release the switch. The display will show
SEN-1043 F
,
SEN-1043 C
,
SEN-1044 F
, or
SEN-1044 C
.
•
Press and release the switch until the desired setting is displayed.
•
Press and hold the switch to save the setting.
warning
High oil temperature warning setup
•
Press and release the switch until “
warning
” is displayed, then press and hold the switch until the display blanks.
•
Release the switch. The display will
show “
hi
”, the current warning (225F – 375F), and “
warning
”.
•
Press and release the switch to change the value, press and hold the switch to select it.
test
Resistance test
•
Press and release the switch unt
il “
test
” is displayed, then press and hold the switch until the display blanks.
•
Press and release the switch to change the gauge. Press and hold the switch to exit.
fuel
Fuel level setup menu
•
Press and release the switch until “
fuel
” is displayed, then press and hold the switch until the display blanks.
•
Release the switch. The display will
show “
sender
”, “
range
”, “
light
”, “
test
”, or “
DONE
”.
•
Press and release the switch to change the selection, press and hold the switch to select it.
Sender
Fuel sender selection
•
Press and release the switch until “
sender
” is displayed, then press and hold the switch until the display blanks.
•
Release the switch. The display will show
“
HD 08
” (2008-2013), “
HD 04
” (2004-2007), or “
custom
”.
•
Press and release the switch until the desired setting is displayed.
•
Press and hold the switch to save the setting. If
CUSTOM
is selected, you will be prompted to save the empty (
SET 00
) and full
(
SET 99
) readings for your tank.
range
Distance to empty setup
The range read
ing will initially show the word “
range
” until a tank of gas has been driven to allow the gauge to
complete its setup based on your driving. Begin with a full tank of gas and do not refill it until it gets below ¼ tank of gas. This
can be done on multiple trips as long as no fuel is added before it gets low enough. After the initial setup the display will show
“
E
” followed by the calculated distance to empty. This will count down, making adjustments as necessary, until the range is 35
miles (56km) or le
ss and then it will show “
r low
”. The gauge will continue to make adjustments to match your driving habits
with each fill up. After the initial setup you are not required to wait for the fuel to get below ¼ tank before refilling.
•
Press and release the sw
itch until “
range
” is displayed, then press and hold the switch until the display blanks.
•
Release the switch. The display will
show “
OFF
” or “
On
” indicating whether the feature is active.
•
Press and release the switch to change the value, press and hold the switch to select it.
•
If
ON
is selected, the next option is “
done
” or “
reset
” “
learning
”. To reset or start a new distance learning cycle, select “
reset
learning
” and hold the switch.
light
Low fuel light setup
The low fuel indicator can be turned on or off, and the fuel level when it activates can be adjusted.
•
Press and release the switch until “
light
” is displayed, then press and hold the switch until the display blanks.
•
Release the switch. The display will
show “
OFF
” or “
On
” indicating whether the feature is active.
•
Press and release the switch to change the value, press and hold the switch to select it.
•
If
ON
is selected, the next option is “
xx%
”, “
reset
”, or “
adjust
”.
o
Xx%
is the current low fuel warning set point.
o
RESET
will return the set point back to the default 25%
o
ADJUST
will select the current fuel level as the low warning set point.
test
Gauge reading test
•
Press and release the switch until “
test
” is displayed, then press and hold the switch until the display blanks.
•
The calculated fuel level from 0
– 99% will be shown. Press and hold the switch to exit.
Voltage
Low voltage warning setup
•
Press and release the switch until “
VOLT
” is displayed, then press and hold the switch until the display blanks.