background image

Switch  

Position 

Output function 

ON 

1A momentary 1B latching 

 

OFF 

1A and 1B are toggling momentary  

ON 

2A momentary 2B latching 

 

OFF 

2A and 2B are toggling momentary  

ON 

3A momentary 3B latching 

 

OFF 

3A and 3B are toggling momentary  

ON 

4A momentary 4B latching 

 

OFF 

4A and 4B are toggling momentary  

ON 

5A momentary 5B latching 

 

OFF 

5A and 5B are toggling momentary  

ON 

6A momentary 6B latching 

 

OFF 

6A and 6B are toggling momentary  

Terminal Connection 

GND chassis 

ground 

PWR 

to co12V power 

IGN 

to key on +12V power 

1A 

grounding(-) output to relay 
coil 

1B 

grounding(-) output to relay 
coil 

2A 

grounding(-) output to relay 
coil 

2B 

grounding(-) output to relay 
coil 

3A 

grounding(-) output to relay 
coil 

3B 

grounding(-) output to relay 
coil 

4A 

grounding(-) output to relay 
coil 

4B 

grounding(-) output to relay 
coil 

5A 

grounding(-) output to relay 
coil 

5B 

grounding(-) output to relay 
coil 

6A 

grounding(-) output to relay 
coil 

6B 

grounding(-) output to relay 
coil 

 
 
 
 
 

 

2

Содержание COMMANDER Series

Страница 1: ...CMDX COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM MAN 650026 A ...

Страница 2: ...y 6 ON 6A momentary 6B latching OFF 6A and 6B are toggling momentary Terminal Connection GND chassis ground PWR to constant 12V power IGN to key on 12V power 1A grounding output to relay coil 1B grounding output to relay coil 2A grounding output to relay coil 2B grounding output to relay coil 3A grounding output to relay coil 3B grounding output to relay coil 4A grounding output to relay coil 4B g...

Страница 3: ...is on to avoid the accidental opening of a door or some other undesired function during vehicle operation With the ignition on the only functions that are allowed to work are outputs 1A 1B 2A and 2B The ignition will disable all other outputs and keep latched outputs at their current state on or off ADDITIONAL TRANSMITTERS The transmitters supplied with your remote system have a unique serial numb...

Страница 4: ...urce to disable outputs 3 6 to prevent accidental function while the key is on The CMDX should only be connected to a 12 volt battery for power and never solely to a battery charger All outputs are grounding or negative outputs designed to ONLY turn on external relays NEVER DIRECTLY CONNECT A CMDX OUTPUT TO A MOTOR SOLENOID LIGHTS OR SIMILAR LOAD INTERNAL CIRCUIT DAMAGE WILL RESULT Figure 1 shows ...

Страница 5: ...hicle the CMDX system can be used to control them All outputs need to be wired through an external relay Latch motors and actuators also need to be connected to a momentary output NEVER hook a latch actuator to a latching output or motor damage could result All of the relays in Figure 2 are connected to A outputs or momentary outputs to ensure the latch motor is only powered while a button is pres...

Страница 6: ...rness without the remote system Once the power windows are working correctly with the supplied switches then connect the remote system relay packs to the harness This will simplify correcting any wiring problems that may show up FIGURE 4 Connection to Specialty Downs Balls GM and other power window regulators using a 5 wire or center position grounding switch This wiring diagram can be used with m...

Страница 7: ...FIGURE 5 Connection to power window regulators with a three wire 12 volt switch FIGURE 6 Connection to power windows with 4 wire switch not center position grounding 7 ...

Страница 8: ...here are two single and two dual relay packs included with the CMDX There are additional relays available from Dakota Digital RLY 1 RLY 2 however any 12 volt automotive relay will work This diagram will show how to wire a relay to supply 12V to the desired load Depending on the desired operation a latching or momentary output could be used FIGURE 8 Connection to relays for operating accessories wi...

Страница 9: ...included with the base package These are sold separately if needed for your application The CMDX should be setup for momentary toggling outputs to operate door lock motors extended power to the lock motor could damage the motor FIGURE 9 Connection to power door locks with 3 wire 12V switch FIGURE 10 Connection to power door locks with 3 wire grounding switch 9 ...

Страница 10: ...POWER DOOR LOCK WIRING FIGURE 11 Connection to power door locks with a 5 wire switch TRANSMITTER BUTTON NUMBERING OUTPUT CONTROLLED 10 ...

Страница 11: ...e the vehicle is in motion if connected to the appropriate output OPERATION FOR MODE 2 DIP switch ON momentary and latching outputs The key chain transmitter has six buttons They are labeled with roman numerals I II III IV V and VI The red light next to the programming switches will flash once briefly each time a button is pressed to verify the command has been received Button I controls outputs 1...

Страница 12: ...cation of a weak battery is that the red indicator may have a dim glow to it when any button is pressed The battery is replaced in the following manner 1 Use a small straight screwdriver to pry the two halves apart at the key ring attachment 2 Carefully separate the two case halves 3 Remove the battery noting the and position 4 Replace the battery with a new 12 volt type GP23A battery which is ava...

Страница 13: ...13 10 When you are finished turn the ignition key off to exit the programming mode and restart the system ...

Страница 14: ...f the defect s To obtain repair or replacement within the terms of this Warranty the product is to be delivered with proof of warranty coverage e g dated bill of sale specification of defects transportation prepaid to the factory This Warranty is valid for the original purchaser only and may not be transferred This warranty does not cover batteries nor extend to damage to vehicle electrical system...

Отзывы: