background image

Manual #650506b 

To set or change the ID number: 
 

The ID will not normally need to be changed.  A green-red-red flash on the BIM-17-2 status light indicates an ID 

conflict with another connected BIM.  The following procedure will allow the BIM-17-2 to automatically select a new, 
unused ID. 

 

Hold the switch on BIM while turning the key on.  The BIM status light will be steady RED. 

 

Release the switch.   

 

When the status light begins flashing, it is finished.  

 

VFD/VHX wiring tip: 

When connecting to a VFD or VHX display system with the round 3.5mm jack you can easily get power and 

ground from the control box FUEL+ and FUEL- terminals.  These terminals are normally not used.  Connect the BIM-xx-1 
adapter harness RED wire to the FUEL+ terminal and connect the BIM-xx-1 adapter harness BLACK wire to the FUEL- 
terminal. 
 
Troubleshooting quick tips: 

While the BIM is operating, the status light will flash green.  A steady green indicates it is powered up but not 

receiving any bus activity. 
The display will flash green-yellow-green-yellow-red-red (rapid red flash with slow green flash) until it has been calibrated 
in your vehicle.  It cannot begin reading correctly until after this is completed. 
A flashing yellow-red (steady red with a flashing green) indicates an open or shorted temperature sensor connection. 
 
Interference notes: 

Traffic light sensors mounted into the road can cause a temporary error in the compass heading.  The reading will 

correct itself once you have driven off the road sensor. 
Bridges can cause temporary interference due to the steel supports. 
Steel reinforced concrete can cause interference if the module is mounted too low in the vehicle. 
If the compass is always showing interference, even in open areas, then repeat the compass calibration.  If this does not 
resolve the problem then move the BIM-17 to a different location and then repeat the compass calibration. 
 

Troubleshooting guide. 

Problem   

 

Possible cause 

 

 

Solution   

 

 

 

 

 

Sensor does not show on 

PWR wire does not have power. 

Connect to a location that has power. 

  gauge readout. 

 

GND wire does not have a good 

Connect to a different ground location. 

  BIM will not light up at all. 

  ground. 

 

 

 

Power/data harness is damaged. 

Inspect harness.  Repair or replace any damaged areas. 

 

 

 

Module is damaged. 

 

Return for service.  (see instructions) 

 

 

 

Sensor does not show on 

Interface cable is not connected. 

Connect the supplied 3.5mm data cable between the module and  

  gauge readout. 

 

 

 

 

 

  the gauge control box. 

  BIM has a steady green 

Interface cable is loose. 

 

Make sure both ends of the cable are seated in securely. 

  light. 

 

 

Another BIM is set with the same  

Test module works when connected to control box alone.  Change ID 

   

 

 

 channel ID. 

 

 

  on one of the modules so each module uses unique ID. 

 

Sensor does not show on 

Another BIM is set with the same  

Test module works when connected to control box alone.  Change ID  

  gauge readout. 

 

channel ID. 

 

 

  on one of the modules so each module uses unique ID. 

  BIM light is flashing  

 

  green-red-red 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compass shows interference  Compass is not calibrated correctly. 

Follow Compass calibration instructions on third page. 

 at all times. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compass reads incorrectly. 

Compass is not calibrated correctly.  

Follow Compass calibration instructions on third page. 

 

 

 

True North offset is incorrect.   

Change the North offset to correct the compass heading. 

 

 

Gauge lights up, but does 

Loose connection on sensor wires. 

Inspect and reconnect wires. 

  not read correctly.   

Air temperature sensor is not getting 

Change the mounting location of the air temperature sensor to get 

  

 

 

  proper air flow. 

 

 

  good air flow and avoid heat from the engine. 

 

 

 

Gauge lights up, but displays  SENDER terminal is shorted to ground.  Check wire for damaged insulation.  Replace if necessary. 
  “---”.  

 

 

Sender is damaged.  

 

Replace sender. 

 

 

 

 

 

 

Gauge lights up, but displays  Sender is not connected to gauge. 

Connect SND terminal on gauge to sender terminal. 

  “EEE”.    

 

Wire between gauge and sender is 

Test and replace wire. 

 

 

 

  broken. 

 

 

 

Sender is damaged.  

 

Replace sender. 

 

 

 

Module is damaged. 

 

Return module for service.  (see instructions) 

 

 

 

Gauge lights up, but displays  The temp sender is not connected. 

Check wire connections to the temperature sender. 

  “-40F”.    

 

Sender is damaged.  

 

Replace sender. 

 

 

 

 

 

 