Manual #650506b
For HDX systems follow these steps:
•
Make sure the BIM units are all connected to the gauge control box.
•
With the ignition on, press and hold both switches to enter SETUP. With external switches hold either one while
turning the ignition on. Release the switches when SETUP is shown.
•
Press and release either switch until BIM is selected. Press and hold either switch to enter BIM setup menu.
•
Release the switch. A list of the BIM’s found should be shown. If NONE FOUND is displayed then check
connections to the BIM-17-2.
•
Press and release either switch until BIM-17 is selected. The status LED on the BIM will flash RED-GREEN.
•
Press and hold either switch to enter the BIM-17 setup.
•
Release the switch. The menu will show LABEL, WARN LO, N OFFSET, CALIBRATE, BACK. Any menu that
does not apply to this BIM will be grey and cannot be selected.
•
To change the temperature low warning point, press and release either switch until WARN LO is selected.
•
Press and hold either switch to change the WARN LO setting.
•
Release the switch. The message display will show the current low temperature warning.
•
Press and release either switch to change the 0 V display setting to the desired value.
•
Press and hold either switch to go back to the previous setup menu.
•
Release the switch.
•
To change the true north offset correction, press and release either switch until N OFFSET is selected.
•
Press and hold either switch to change the north offset setting. The previous chart shows offset values for the
United States.
•
Press and release either switch to change the north offset setting to the desired value.
•
Press and hold either switch to go back to the previous menu.
•
Release the switch.
•
To calibrate the compass to your vehicle, press and release either switch until CALIBRATE is selected.
•
Release the switch. The display will show DRIVE IN CIRCLES. Begin slowly driving in a circle in an open area.
Drive in at least two slow, complete circles.
•
Momentarily press either switch to finish and save the compass calibration.
•
Select BACK to return to the BIM list menu.
•
Select BACK to return to the main menu.
•
Select EXIT SETUP to return to normal operation.
With HDX systems the setup can also be done with the Dakota Digital app for Apple and Android devices.