[10]
MAN #650695
Quick tips:
While the BIM is operating, the dot in the upper left corner of the display will indicate the status:
•
On steady indicates it is powered up but not receiving any BIM bus activity.
•
Flashing indicates it is communicating on the BIM bus.
•
A dot in the upper center indicates that there is an engine code set (MIL active).
•
If the display shows
“BUS”, then it is scanning to try and communicate with the vehicle bus but cannot get an
answer.
o
This could indicate that the ODBII connector is not wired properly
o
The BIM-01-2-J1939 is not compatible with the ECU
To see the sensor and channel status on the BIM display, press and hold the switch to cycle through the screens.
The screen will display the data that is available:
“
” - Engine Oil Pressure
“
” – Engine Coolant Temp
“
” - Ambient Air Temp
“
” - Intake Air Temp
“
” - Gear Position
“
” - Fuel Level Input
“
” - Boost/Vacuum data
“
” – Fuel Pressure
“
” - RPM/Tachometer data
“
” – Oil Temp
If you do not see any number of these listed it means it may not be transmitted for the BIM-01-2-J1939 to read.
Emissions note:
If your vehicle requires emissions testing in your area, the check engine feature of this unit cannot be used to operate the
Check Engine or Service Engine indicator.
Troubleshooting guide:
Problem
Possible cause
Solution
No BIM data on instrument readout;
BIM does not light up.
PWR wire does not have power.
GND wire is not properly grounded.
Power/data harness is damaged.
Module is damaged.
Connect to a location that has +12V key-on power.
Connect to a different ground location.
Inspect harness. Repair or replace any damaged
areas.
Return for service. (see instructions)
No BIM data on instrument readout;
BIM display is sca
nning “BUS”
CAN Interface cable is not connected.
Connect the supplied CAN interface cable between
the BIM unit and the ECU
’s CAN output.
No BIM data on instrument readout;
BIM has a steady dot lit.
Interface cable is not connected.
Interface cable is loose.
On VHX systems, the BIM display for
this channel is disabled.
Connect the supplied harness between the BIM
unit and the instrument system control box.
Ensure both ends of the cable are seated securely.
Follow instructions in VHX manual to enable the
BIM display screen.
BIM d
isplay shows “
:
”
Data cable is damaged or connected
improperly.
Another module on the bus is damaged.
Inspect and replace harness or power/data
harness.
Inspect other modules on the data bus.
Содержание BIM-01-2-J1939