background image

CONNECTING AN EXTERIOR DETECTOR:

The UT-2500 can be activated by any type of detector which provides a 
normally open (N/O) or normally closed (N/C) output. 
1.   Locate the terminals at the bottom of the case. (Figure 3)
2.   Insert the wires through the silicone gasket and make the 

connections on the terminals.

Note: A 22 AWG solid wire can be used to easily pierce the 
silicone gasket. If using a lighter wire you may need to pierce the 
gasket with a paper clip or small needle.

3.   For a normally closed (N/C) connection, connect the wires to the 

NC and Common (center) terminals.

4.   For a normally open (N/O) connection, connect the wires between 

the NO and Common (center)terminals.

USING THE MAGNETIC CONTACT:

The magnetic contact can be used on most doors/windows with a gap of less than 
12mm.
1.   Mount the push button on the door jam with the screws provided.
2.   Mount the magnet on the door (within 12mm of the push button) with the 

screws provided.

3.   After mounting the magnet on the door snap the cover on the magnet case.
4.   The magnetic contact can be used on either side of the push button. (Figure 4)

USING MULTIPLE DETECTORS:

If multiple normally closed (N/C) contacts are to be used, they should be run in series to the N/C contacts. If 
multiple normally open (N/O) contacts are used, they should be run in parallel to the N/O contacts.

Note: Both N/O and N/C contacts can be used simultaneously along with the magnetic contact and 
push button.

MOUNTING THE TRANSMITTER:

The transmitter can be mounted to any wall using the mounting 
bracket. (Figure 5)

The mounting bracket is located on the back of the UT-2500 and can 
be removed by simply sliding it off. Position the bracket were you 
would like it and place two screws in the holes provided. To place the 
UT-2500 back simply slide it over the bracket.

If mounting the UT-2500 outdoors it is recommended to place the 
silicone plugs in the screw holes at the back of the case to prevent 
moisture from entering the case. 

Universal Transmitter 
Model No.: UT-2500 
Voltage: 3V===20mA 
Operating Range: -34°C to 48°C

FIGURE 3

TERMINALS

FIGURE 4

FIGURE 5

UT BACK COVER

MOUNTING

BRACKET

Содержание UT-2500

Страница 1: ... with Part 15 of the FCC rules operation of this device is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference including interference that may cause undesired operation UT 2500 Universal Transmitter Owners Manual ...

Страница 2: ...red zone tune and relay output See Coding the transmitter for info on setting the dip switches INSTALLING THE BATTERY 1 Use only a CR 2 3 Volt Lithium battery 2 Be sure to observe proper polarity when installing the battery LED INDICATOR LIGHT IN BUTTON 1 The default setting is for the LED indicator to light up for two seconds when the UT 2500 is activated 2 To deactivate the LED press and hold th...

Страница 3: ...he magnet on the door snap the cover on the magnet case 4 The magnetic contact can be used on either side of the push button Figure 4 USING MULTIPLE DETECTORS If multiple normally closed N C contacts are to be used they should be run in series to the N C contacts If multiple normally open N O contacts are used they should be run in parallel to the N O contacts Note Both N O and N C contacts can be...

Страница 4: ...y TECHNICAL SUPPORT If you encounter any difficulty in the operation of this product after reading the manual please contact us We will be happy to answer your questions and help you in any way we can WARRANTY Dakota Alert warrants this product to be free of defects in material and workmanship for a period of one year from the date of purchase This warranty does not cover damage resulting from acc...

Отзывы: