Страница 1: ...DakotaAlert WIRELESS SECURITY EQUIPMENT Solar Break Beam Transmitter SBB 4000 USER GUIDE ...

Страница 2: ...s and Lock Washer 8 M4x40 Pan Head Screws 8 M4 Nut 4 Metal Pipe Mounts 4 Pipe Mount Rubber Adapters 2 C Mounting Brackets User Guide X 8 X 2 M4x10 Pan Head Screws with Flat Washers and Lock Washers M4x40 Pan Head Screws with Nuts X 8 X 4 X 4 Metal Pipe Mounts Pipe Mount Rubber Adapters C Mounting Brackets NOTE Remove the protective plastic covering the lenses and solar panels ...

Страница 3: ...ease the power button on the B sensor The LED will start flashing 3 Press and release the power button on the A sensor and the LED will start flashing green 4 When the LED stops flashing on the A sensor the pairing is complete about 30 seconds 5 Test the pairing by completely blocking the beams A piece of carboard can be used or physically move the beams so they are not aligned The LED on the A se...

Страница 4: ... are continuously interrupted the A sensor will send a reminder signal to the receiver The factory default is to send a signal every 20 seconds if the beams are continuously interrupted 2 To change the reminder duration to 5 minutes press and hold the power button of the A sensor for 5 seconds then release The LED will start flashing red 3 To change back to the 20 second reminder duration press an...

Страница 5: ...to a flat surface Use appropriate screws or fasteners not included to mount the back of the C bracket directly to a flat surface such as a wall or wood post Mounting to a pole or pipe Use the provided screws M4x40 Pan Head Screw and Nut pipe mount and rubber adapter to connect the C bracket to the pipe Side View of Pipe Mount Sensors should be facing each other at approximately the same height COR...

Страница 6: ...r to help achieve alignment After rotating the sensors re tighten the screws 5 If the beams are paired you will get a signal when you walk between the beams If you get a signal every 20 seconds 5 minutes optional this is the reminder signal and the beams are not aligned Slightly reposition the beams until the reminder stops and the beams are activated by walking between them MOUNTING SENSORS TO TH...

Страница 7: ...t a USB Micro charger not included to the port 4 Once finished charging insert the rubber plug back into the recess NOTE You can either leave the charger connected indefinitely or you can fully charge the beams periodically When the beams are fully charged the built in batteries will usually hold a charge for about a month depending on activations RECHARGING THE BEAMS Charging Port Under Rubber Pl...

Страница 8: ...the A sensor away from large metal objects that may interfere with the radio signal Specifications Power source 18650 rechargeable lithium battery solar charger or USB Micro not included Frequency 433 92 MHz Wireless range up to 1 mile Maximum detection range Up to 300 feet Operating temperature 20 to 120F Actual range will vary depending on local terrain and obstructions Tech Support If you have ...

Страница 9: ... could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed a...

Страница 10: ...n be distinguished by the sound you hear The receiver also has two form C relay outputs as well as one 12 VDC output The outputs can be selected for 1 5 15 seconds or 5 minutes Each sensor can be set to independently select the output s time duration sound and flashing LED An extra receiver can be placed in an out building or on a different floor of your home PR 4000 Portable Receiver The PR 4000 ...

Страница 11: ...r either a normally open N O or a normally closed N C input These inputs can be used with any sensor contacts DCPT 4000 Transmitter The DCPT 4000 transmitter operates on three CR 123A batteries included and has 50 feet of direct burial wire connecting the probe to the exterior case The probe is buried parallel to the driveway It detects vehicles passing by within approximately 10 12 feet DCRH 4000...