![DAITEM SC901AU Скачать руководство пользователя страница 21](http://html2.mh-extra.com/html/daitem/sc901au/sc901au_installation-manual_3065933021.webp)
23
TIP
• All terminal blocks can be unplugged to facilitate wiring.
• The connections to be made are summarised on a label inside the controller cover.
4. Connecting an electrical latch
Connect the latch according to the following cable cross-sections:
- in 3 and 4: 0.75 mm
2
up to 15 m/1.5 mm
2
up to 30 m,
- in 5, 6, 7 and 8: 0.22 mm
2
(telephone type wire).
3.5
3
4
5
6
7
8
12 V
0.5 A max.
-
+
NC
Electrical latch or lock
control (no need for
external power supply)
The position contact feeds back
the latch status to the screen:
-
latch closed (contact closed),
-
latch open (contact open).
Push-button located on the garden side
for manual latch control. Place this control
device out of reach and sight in relation
to the road (connection not compulsory).
IMPORTANT: for the information feedback to be
properly managed, the position contact (ref. CP500
on the price list) must be wired before power-up
and be in closed position when the radio link is
established between the handset and the controller.
If no contact is connected, the handset display will
show the latch is closed whatever its status.
IMPORTANT: so that the system
recognises the latch, it must be
wired before the radio link is
created between the handset
and the controller.
3. Connecting the outdoor caller unit
Connect the 4 outdoor caller unit
wires to terminal blocks
15 to 18 on the controller.
3.5
15 16 17 18
-
+
((
((
((
((
15/Green: Data –
16/Yellow: Data +
17/Red: power +
18/Black: power –
TIP: if the cable between the outdoor caller unit and the controller has to be extended, keep or shorten
the length of the cable supplied and then connect the wires to a branch box in accordance with the
rules below:
• up to 10 m (including the remaining length of the original cable): use 4 x 0.32 mm² cross-section cable
(AWG22) for the 4 wires
• from 10 to 15 m (including the remaining length of the original cable):
- use 2 x 0.75 mm² cross-section cable (AWG18) for the supply wires (red and black),
- use standard 2 x 0.16 mm² bunched cable (AWG25) with an impedance Z of 124
Ω
for the Data wires
(green and yellow)
• from 15 to 25 m (including the remaining length of the original cable):
- use 2 x 1.5 mm² cross-section cable (AWG15) for the supply wires (red and black),
- use standard 2 x 0.16 mm² bunched cable (AWG25) with an impedance Z of 124
Ω
for the Data wires
(green and yellow).
Podpowiedź:
W celu ułatwienia podłączenia przewodów można wyjąć listwę połączeniową z kontrolera.
Opis podłączenia poszczególnych przewodów znajduje się również na pokrywie kontrolera.
Podłączanie panelu zewnętrznego.
Podłącz 4 przewody od panelu
do zacisków 15 do 18 zgodnie
z kolorami.
Podłączanie elektrozamka.
WAŻNE: System rozpoznaje
podłączenie elektrozamka
dlatego musi on zostać
podłączony zanim sparujemy
radiowo słuchawkę z
kontrolerem.
Zaciski do podłączenia przycisku
na wyjście (opcjonalnie)
Elektrozamek
nie wymaga
osobnego zasilania
Czujnik pozycyjny informuje o tym,
czy brama jest otwarta, czy nie:
brama zamknięta
brama otwarta
Ważne: Czujnik pozycyjny CP500 musi być podłączony,
zanim system zostanie zasilony oraz musi być
zamknięty zanim zostanie nawiązana komunikacja
radiowa pomiędzy kontrolerem, a słuchawką.
W przeciwnym razie słuchawka nie będzie prawidłowo
wyświetlała jego stanu.
15 Zielony
16 Żółty
17 Cz
18 Czarny -
Podłącz elektrozamek zgodnie z podanymi zaleceniami:
styk 3 i 4:
do 15m,
do 30m.
styk 5,6,7 i 8:
Содержание SC901AU