Daishiba DSP-85HA Скачать руководство пользователя страница 10

 

- 9 - 

Electric connection 

 

 

 

 

 

 

A heat pump must not be connected without the permission of the electricity supplier and must 

be connected under the supervision of a qualified electrician. 

Wires, spare parts and materials etc. must satisfy the relevant standards issued by the host 

country or region. 

The heat pump does not include an isolator switch on the incoming electrical supply. The power 

supply cable must be connected to a circuit

breaker with at least a 3 mm breaking gap. 

Incoming supply must be 220V 1

phase, neutral ground, via a distribution board with fuses. 

 

 

If an insulation test is to be carried out in the building, please make sure to disconnect the heat 

pump. 

To avoid the possibility of false action caused by electromagnetic coupling, the communication 

wire must be STP (Shielded Twisted Pair).The size of communication wire should not less than 

0.5mm

2

 

Note!

 

Electrical installation and service must be carried out 
under the supervision of a qualified electrician. Electrical 
installation and wiring must be carried out in accordance 
with the stipulations in force.

 

Содержание DSP-85HA

Страница 1: ...Air Source Swimming pool Heat Pump Installation and Operation Manual DSP 85HA DSP 100HA DSP 120HA...

Страница 2: ...1 Content Safety Precautions 2 Technical data 3 Unit dimension 4 Installation 5 Sound pressure level 8 Electric connection 9 Controller instruction 11 Maintenance Troubleshooting 15...

Страница 3: ...n of installation is stable If the foundation is unstable the outdoor unit may drop and cause a casualty Make sure that the electric leakage protection switch is fixed If no electric leakage protectio...

Страница 4: ...nning Temp Range 5 43 Unit Dimension W H D mm 615 1060 370 Net Weight KG 55 62 70 Noise dB A 52 54 54 Water Inlet Outlet Dimension 50 8 2 Water Heat Exchanger Titanium Min Water Flow L MIN 60 72 80 Re...

Страница 5: ...4 Unit dimensions Model A mm B mm C mm D mm E mm DSP 85 HA DSP 100 HA DSP 120HA 650 1140 415 435 684...

Страница 6: ...al safety 4 Ensure the unit is well ventilated direction of air exhaust is kept away from windows of neighboring buildings and the exhaust air cannot flow back Moreover adequate service clearance shou...

Страница 7: ...6 Installation in exceptional circumstances unit mm No obstacle in front of the unit Obstacle above the unit Obstacle in front of the unit Several units in a row...

Страница 8: ...7 Installation diagram Installation diagram for combination...

Страница 9: ...d a place on the side that faces the least sound sensitive neighbor area The sound pressure levels are further affected by walls bricks differences in ground level etc and should therefore only be see...

Страница 10: ...er with at least a 3 mm breaking gap Incoming supply must be 220V 1 phase neutral ground via a distribution board with fuses If an insulation test is to be carried out in the building please make sure...

Страница 11: ...10 Circuit drawing...

Страница 12: ...me When the timer on timer off are set press this button the unit will start or stop according to the set time everyday Press again to cancel it Time Press time button it shows clock Press up or down...

Страница 13: ...FF to quit defrosting mode compulsively Note the unit is of defrosting automatic function so only when defrosting incompletely in winter is the compulsively defrosting needed This operation must be fo...

Страница 14: ...ting end temp adjustment 2 25 12 P07 Defrosting interval time adjustment 20 80 min 45min P08 Defrosting running time adjustment 3 15 min 6min P09 Compressor exhaust protection temp adjustment 100 125...

Страница 15: ...0 No 1 Yes 1 P54 Function selecting of exhaust temp protection 0 No 1 Yes 1 P55 Water flow switch 0 No 1 Yes 1 P56 Water pump open constantly option 1 open constantly 0 open close normally 1 Adjust th...

Страница 16: ...ating exchanger regularly to maintain good heat exchange as conserve energy The operation pressure of the refrigerant system should only be serviced by a certified technician Check the power supply an...

Страница 17: ...07 Outlet water temp E09 Water flow insufficient E10 Communication failure E14 Compressor exhaust temp E25 Outlet water overcooling protection in the cooling mode E26 Outlet water overheating protecti...

Отзывы: