[25]
Rev 4/15/14
Dairy Tech, Inc.
Service Manual:
DT10G, DT30G &DT60G
Instructions for Adding a New Profile –
Don’t reset to factory defaults!
A new profile may be desired for special circumstances on a dairy that call for variations in
temperature, time of cycles, time of day to start a cycle automatically, or complex profiles that allow
multiple functions.
New Profiles must be written according to the controller code and is normally done by Dairy Tech
trained personnel and the new profile is sent to the dairy or dealer via email. This file can then be
loaded onto a memory stick and inserted into the UBS port on the front of the control.
Instructions for downloading a new profile to your Dairy Tech Pasteurizer from a
USB memory stick -
Don’t reset to factory defaults!
Step 1. You must start with a memory stick that has been initialized by the West control on your Dairy
Tech pasteurizer. To do this, simply turn on the pasteurizer so that the control lights up. Insert your
memory stick into the front of the machine by gently prying off the rubber protective cap that covers
the USB port on the front lower right of the control.
Insert the memory stick and the control will display the message “initializing memory stick …
do not remove”. The unlock code is 10. When it is finished it will ask you to press the return button.
Now the controller has configured your memory stick with the appropriate files so that it can handle
data that is usable by the control. Remove the memory stick , hold the enter button and press the up
arrow twice to return to the main screen then power down the control.
Step 2
.
DO NOT ATTEMPT TO OPEN THE PROFILE ON YOUR COMPUTER! FILE LANGUAGE
WON’T BE RECOGNIZED BY YOUR COMPUTER & MAY HARM THE FILE!
Insert your memory stick into your computer so that you can open the email with your custom file on it
and save to the memory stick. You may have to go into the USB drive for the memory stick and make
certain that the new profile file is saved into the correct place. When you initialized the memory stick it
created a large file called DEVICE. Inside this are 3 sub files: RECORDER, CONFIG and PROFILE.
You will want to make sure that you save your new custom profile into the PROFILE folder.
Step 3. Now you can insert the memory stick into a West control on a Dairy Tech pasteurizer. It will
once again initialize. The unlock code is 10.
Scroll down to READ PROFILE FILE … press ENTER
Select the new file from the list or it may be the only one … press ENTER
It will ask CONFIRM READ? Scroll to YES and press ENTER
Wait while the control reads the file and shows TRANSFER SUCCESSFUL… press ENTER
Remove the memory stick and replace the rubber cap over the USB slot.
Hold the ENTER button while pressing the UP arrow twice to return to the front screens
Step 4. Use the pasteurizer normally and choose the new profile from the list of options when running
a profile.
Содержание DT10G
Страница 2: ...2 Rev 4 15 14 Dairy Tech Inc Service Manual DT10G DT30G DT60G...
Страница 31: ...31 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz USA Domestic...
Страница 32: ...32 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz England Japan...
Страница 33: ...33 Rev 4 15 14 Schematic for Model DT10 30 60G 400VAC 3P Europe...
Страница 34: ...34 Rev 4 15 14 NOTES...
Страница 38: ...38 Rev 4 15 14...