Tetra
®
MAX
Installation Guide
4
Electrical Connections
NOTE: Do not use connectors pre-filled with silicone grease/mineral base protective grease or use silicone grease
to seal connections.
To LED
power
supply
Red (+)
Black or blue (-)
Red Stripe (+)
Cap wires
Optional: Cut wires flush
Connect LED strips using in-line (IDC) connectors
or twist-on wire connectors.
NOTE: Seal all connections in wet locations with
electrical grade RTV silicone.
Must cap all exposed wires with appropriate wire
connectors and seal with electrical grade RTV
silicone. Optional: Cut wires flush to the module
and seal with electrical grade RTV silicone.
Run a wire from the LED power supply to the LED
module and connect.
NOTE: Must be used with Class 2 24 Volt Power
Supplies.
NOTE: Refer to Maximum Loading & Remote
Mounting Specifications on page 5.
Connect the red stripe wire (+) of the LED strip
to the red wire (+) of the power supply. Connect
the white wire (-) of the LED strip to the black or
blue wire (-) of the LED power supply.
NOTE: All electrical connections should be
suitably protected from mechanical damage
and the environment. Seal all connections in wet
locations with electrical grade RTV silicone.
LED
Power
Supply
To Tetra LED System
Red (+)
Black or blue (-)
Red stripe (+)
White (-)
White (-)
Seal all connections in wet locations
with electrical grade RTV silicone
Seal all connections in wet locations
with electrical grade RTV silicone
OPTIONAL
A Weather Box (GEXNWB2) may be used
to house and seal Class 2 connections as
described below:
A) Insert wire connectors into weather box. Fill
with electrical grade silicone and close box.
B) Secure the weather box using a #6 or #8
(M2 or M3) screw.
Weather box
can be painted
Light engine
A
B
2
1
3