Arize
®
Factor
Installation Guide
7
Connect the output of the driver to the first light bar using the 30” interconnection
cable. The output of first light bar (6” cable) must be connected to the 30” cable of
the 2nd lightbar, and so on.
For ML900, only 2 lightbars should be connected as shown.
For ML300, a minimum of 4, and a maximum of 6 light bars can be connected.
Connect the shorting cap to the last 6” lightbar cable, as shown, or else the array will
not light. The shorting cap must be secured such that it does not touch the light bar.
Shorting Cap Installation
ML900 Electrical Connection: 2 Lightbars only
Shorting Cap
ML 300 Electrical connection: 4, 5, or 6 Lightbars only
For all configurations greater than 5 bars, only use 3ft or 6ft extension cable (GECA30A14-AA03B or
GECA30A14-AA06B interconnection cables) in conjunction with LED Drivers without NEMA plugs
(GEPSC210-600D-ADGNA-D1XA1 and GEPSC210-600G-AGJNA-D1XA1).
600W
Driver
Lightbar 1
Interconnection cable
Lightbar 2
Shorting Cap
Shorting Cap
600W
Driver
Lightbar 1
Lightbar 3
Lightbar 2
Lightbar 4
Lightbar 5
Lightbar 6
ML300
ML900