Installation Of The Outdoor Unit
As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve
maximum cooling capacity, the location selected for outdoor unit should fulfill the following requirements:
• Ensure that there is no obstruction of air flow into or out of the unit. Remove obstacles which block air
intake or discharge.
• The location must be well ventilated, so that the unit can draw in and distribute plenty of air thus
lowering the condensing temperature.
• A place capable of bearing the weight of the outdoor unit and isolating noise and vibration.
• A place protected from the direct sunlight. Otherwise use an awning for protection, if necessary.
• The location must not be susceptible to dust or oil mist.
Installation Clearances
Dimension
300
A
B
C
D
1000
300
500
Return air
Discha
rge air
A
Obstacle
Obstacle
B
Obstacle
Return air
Service access
D
C
Obstacle
• Outdoor units must be installed such that there is no short circuit of the hot discharge air or obstruction
to smooth air flow.
• Select the coolest possible place where intake air should not be hotter than the outside temperature
(Refer to operating range).
Minimum Distance, (mm)
Note:
If there is any obstacle higher 2m, or if there is any obstruction at the upper part of the unit, please allow more space than the
figure indicated in the above table.
Содержание WinterSpa RHR-C Series
Страница 1: ...Heat Reclaim TM RHR 1214 A TECHNICAL MANUAL...
Страница 11: ...9 TM RHR 1214 A 5 Refrigerant Cycle Diagram...
Страница 14: ...12 TM RHR 1214 A 7 Wiring Diagram Indoor Unit Outdoor Unit Model RHR10CV1...
Страница 15: ...13 TM RHR 1214 A Model RHR15CV1 Indoor Unit Outdoor Unit...
Страница 16: ...14 TM RHR 1214 A Model RHR20CV1 Indoor Unit Outdoor Unit...
Страница 17: ...15 TM RHR 1214 A Model RHR25CV1 Indoor Unit Outdoor Unit...
Страница 18: ...16 TM RHR 1214 A Model RHR30BV1 Indoor Unit Outdoor Unit...
Страница 25: ...23 TM RHR 1214 A Tank Installation Diagram 9 22...