• BS Units • BS UNITS • BSVQ100-250P8B
• VRV
®
Systems • BS Units
4
4
Dimensional drawing & centre of gravity
4 - 1 Dimensional drawing
3
BSVQ250PV1
3D056012A
N
OTES
1
Electric box can also be fixed on the other side of the unit.
2
Be sure to install a inspection door at electric box side.
3
Attached pipe (1) and attached pipe (2) is used in case of
connecting with indoor capacity index more than 160 and less
than 200 In case of connecting one indoor unit of 200 type, only
gas pipe connection port need Attached pipe (1).
4
Small sound will be made when changing over the motor
operated valve, which may be disturbing. Do not install it at the
place such as bedroom under roof.
Nr
Name
Description
1
Suction gas pipe connection port
ø22.2mm brazing connection
2
HP/LP gas pipe connection port
ø19.1mm brazing connection
3
Liquid pipe connection port
ø9.5mm brazing connection
4
Gas pipe connection port
ø22.2mm brazing connection
5
Liquid pipe connection port
ø9.5mm brazing connection
6
Electric box (note 1.)
7
Suspension brackets
M8 ~M10
8
Grounding terminal
M4
9
Attached pipe (1) (Note. 3)
ø19.1mm brazing connection
10
Attached pipe (2) (Note. 3)
ø15.9mm brazing connection
(S
us
pen
si
on bol
t pi
tc
h)
300 or more
(Suspension bolt pitch)
(Servicing space)
Servicing space
Inspection door
(Note 2.)
Location of unit’s name plate - - - right side of electric box
300 or more
(Servicing space)
65
or
mor
e
(S
er
vi
cing
space)
400 or more
(Servicing space)
400 or more
(Servicing space)
(In case of use Attached pipe)
(Ser
vi
ci
ng s
pac
e)
50
or
mor
e
(S
er
vi
ci
ng
sp
ac
e)
(Note 1.)
BSVQ160PV1
3D058004
N
OTES
1
Electric box can also be fixed on the other side of the unit.
2
Be sure to install an inspection door at electric box side.
3
Attached pipe is only used in case of connecting with indoor unit
capacity index 150 or more and 160 or less.
4
Small sound of refrigerant will be made, which may be
disturbing.
Do not install it at the place such as bedroom under roof.
Nr
Name
Description
1
Suction gas pipe connection port
ø15.9mm brazing connection
2
HP/LP gas pipe connection port
ø12.7mm brazing connection
3
Liquid pipe connection port
ø9.5mm brazing connection
4
Gas pipe connection port
ø15.9mm brazing connection
5
Liquid pipe connection port
ø9.5mm brazing connection
6
Electric box (note 1.)
7
Suspension brackets
M8 ~M10
8
Grounding terminal
M4
9
Attached pipe (1) (Note. 3)
ø19.1mm brazing connection
10
Attached pipe (2) (Note. 3)
ø15.9mm brazing connection
(Sus
pens
ion bol
t pi
tc
h)
250 or more
(Suspension bolt pitch)
(Servicing space)
Servicing space
Inspection door
(Note 2.)
Location of unit’s name plate - - - right side of electric box
250 or more
(Servicing space)
65
or
mo
re
(S
ervicing
space)
350 or more
(Servicing space)
350 or more
(Servicing space)
(In case of use Attached pipe)
(S
us
pens
ion bol
t pi
tc
h)
50
or
mo
re
(S
er
vi
ci
ng
sp
ac
e)